Back to results

Virginia Tech

Polymer Composite Spinal Disc Implants

Abstract

dc:description.abstract

The goal of this research study was to create an artificial annulus fibrosus similar to that of the natural intervertebral disc, as well as find preliminary results for vertebral endplate connection and nucleus pulposus internal pressure, for the correction of disc degeneration in the spine. The three-part composite samples needed to demonstrate good shock absorption and load distribution while maintaining strength and flexibility, and removing the need for metal in the body, something of which no current total disc replacement or spinal fusion surgery can offer. For this study, the spinal disc was separated into its three different components, the annulus fibrosus, the nucleus pulposus, and the vertebral endplates, each playing a vital role in the function of the disc. Two low-cost materials were selected, a Covestro polyurethane and cellulose nanocrystals, for the purpose of creating a polymer composite spinal disc implant. A methodology was established for creating the cast composite material for use as an annulus fibrosus, while also investigating its mechanical properties. The same composite material was used to acquire preliminary results for vertebral endplate connection to the synthesized annulus, however no additional material was used to determine or mimic the mechanical properties of these endplates, due to time constraints. Also because of time constraints, the nucleus used in this study was only comprised of water with no other additives for preliminary testing since the natural nucleus is comprised of about 80-90% water. These properties were then compared to the mechanical properties of the natural disc, so that they could be finely tuned to emulate the natural disc. It is shown in this study that the composite material, when swelled in water, was able to mimic the annulus fibrosus in tensile strength and modulus, however showed higher compressive strength and modulus than ideal. The samples also did not undergo any permanent deformation within the realm of force actually introduced to the natural disc. The vertebral endplates showed decent adhesion to the synthesized annulus, however there were slight defects that became failure concentrators during compression testing. The nucleus showed promising results maintaining good internal pressure to the system causing better compressive load distribution, with barreling of the samples.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Materials Science and Engineering
Department dc:contributor.department
Materials Science and Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Frost, Brody A.
Chair dc:contributor.committeechair
  • Foster, Earl Johan
Committee members dc:contributor.committeemember
  • Van Dyke, Mark
  • Goldstein, Aaron

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Creative Commons Attribution-NonCommercial-NoDerivs 3.0 United States
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/78783
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/78783

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Frost, Brody A.. Polymer Composite Spinal Disc Implants. masters thesis, Virginia Tech, 2017. http://hdl.handle.net/10919/78783