Back to results

Virginia Tech

Optimal Substation Coverage for Phasor Measurement Unit Installations

Abstract

dc:description.abstract

The PMU has been found to carry great deal of value for applications in the wide area monitoring of power systems. Historically, deployment of these devices has been limited by the prohibitive cost of the device itself. Therefore, the objective of the conventional optimal PMU placement problem is to find the minimum number devices, which if carefully placed throughout the network, either maximize observability or completely observe subject to different constraints. Now due to improved technology and digital relays serving a dual use as relay & PMU, the cost of the PMU device itself is not the largest portion of the deployment cost, but rather the substation installation. In a recently completed large-scale deployment of PMUs on the EHV network, Virginia Electric & Power Company (VEPCO) has found this to be so. The assumption then becomes that if construction work is done in a substation, enough PMU devices will be placed such that everything at that substation is measured. This thesis presents a technique proposed to minimize the number of substation installations thus indirectly minimizing the synchrophasor deployment costs. Also presented is a brief history of the PMU and its applications along with the conventional Optimal PMU placement problem and the scope for expanding this work.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Department dc:contributor.department
Electrical and Computer Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mishra, Chetan
Chair dc:contributor.committeechair
  • Centeno, Virgilio A.
Committee members dc:contributor.committeemember
  • Thorp, James S.
  • Baumann, William T.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Dc Identifier Other
etd-12112014-150336
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/78056

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Mishra, Chetan. Optimal Substation Coverage for Phasor Measurement Unit Installations. masters thesis, Virginia Tech, 2012. http://hdl.handle.net/10919/78056