Robot gripper control system using PVDF piezoelectric sensors

Abstract

dc:description.abstract

A novel robot gripper control system is presented which uses PVDF piezoelectric sensors to actively damp exerted force. By using a low-input-resistance amplifier to sense the current developed by the PVDF sensor, an output proportional to the rate of change of the force exerted by the gripper is obtained. The signals from the PVDF sensor and a strain gauge force sensor are arranged in a proportional and derivative (PD) control system for the control of force. The control system was tested on an instrumented Rhino XR-1 manipulator hand. The capabilities of the control system are analyzed analytically, and verified experimentally. The results for this particular gripper indicate that as much as 900% improvement in force step response rise time, and 300% reduction in overshoot are possible by inclusion of the PVDF sensor.

Degree

thesis:*
Name thesis:degree_name
Master of Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Electrical Engineering
Department dc:contributor.department
Electrical Engineering
Grantor dc:publisher
Virginia Polytechnic Institute and State University
Year dc:date.issued
1986

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Barsky, Michael F.

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/77897
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/77897

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Barsky, Michael F.. Robot gripper control system using PVDF piezoelectric sensors. masters thesis, Virginia Polytechnic Institute and State University, 1986. http://hdl.handle.net/10919/77897