Back to results

Virginia Polytechnic Institute and State University

Refractometry by total reflection

Abstract

dc:description.abstract

Refractometry is a means to measure the refractive indices of liquids, gases, and dielectric solids, either isotropic or anisotropic, by observation of light refraction or reflection with a microscope, refractometer or other more specialized equipment. For anisotropic solids, refractometry by total reflection (RTR) is by far the simplest, most rapid, and precise method to determine the refractive indices, provided a polished surface of sufficient size exists. Its precision exceeds that for routine oil immersion techniques but compares less favorably to that for minimum deviation methods. However, minimum deviation requires large crystals and, moreover, specifically oriented prisms, one for each principal refractive index to be measured and, for triclinic crystals, one for each wavelength of measurement. The phenomenon of polarized light reflection from randomly oriented anisotropic materials has been modeled because, only after a complete understanding of these phenomena could the R TR method be automated. The mathematics and physics required for this stem from theories and equations presented in the literature of ellipsometry, polarized light, and physical optics. These were then modified, rewritten, and unified to suit the requirements of R TR. RTR, first used by Wollaston ( l 802a, l 802b ), was later perfected for the measurement of the refractive indices and orientation of biaxial minerals in thin section (Viola l 899a, l 899b, 1902; Comu 1901, 1902). RTR with the Abbe-Pulfrich refractometer yielded refractive indices to a precision of ±0.0002, or better. Later, Smith (1905a, 1905b) introduced a simpler refractometer, now known as the jeweler's refractometer, which had a precision of ±0.001 to ±0.002. This refractometer is still in use by gemologists. During this century familiarity with the early work has declined; thus several recent papers display a lack of knowledge of aspects of R TR which were already documented in the early 1900s. A new automated refractometer, designed by Bloss, has precision of ±0.0002 and will be able to measure the refractive indices and orientation of a biaxial mineral in a petrographic thin section. Even for triclinic crystals, a single polished surface arbitrarily oriented will suffice for measurement of all three principal refractive indices, whatever the wavelength supplied. The design and testing of this refractometer has taken approximately three years. Two prototypes have been built and tested. Results from the second prototype are presented.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Geological Sciences
Department dc:contributor.department
Geological Sciences
Grantor dc:publisher
Virginia Polytechnic Institute and State University
Year dc:date.issued
1987

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gunter, Mickey E.
Chair dc:contributor.committeechair
  • Bloss, F. Donald
Committee members dc:contributor.committeemember
  • Eriksson, Susan C.
  • Indebetouw, Guy J.
  • Ribbe, Paul H.
  • Speer, J. Alexander

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/77798
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/77798

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Gunter, Mickey E.. Refractometry by total reflection. doctoral thesis, Virginia Polytechnic Institute and State University, 1987. http://hdl.handle.net/10919/77798