Interfacing of an LSI-11 micro processor with the spectra-physics 3500B gradient elution liquid chromatograph

Abstract

dc:description.abstract

An LSI-11 micro-processor and a Spectra-Physics model 3500B gradient elution liquid chromatography were interfaced for the purpose of automating the chromatograph, incorporating it into the laboratory data network system and collecting data for Michael Starlings' project. The automation involved the construction of hardware for the control of the chromatograph and for data acquisition and display and the writing of software to operate the interface. The LSI-11 collects data by clock interrupts while displaying the current data buffer on the oscilloscope. It stores all data files on a floppy disk storage device, accessed through the main host computer. An analysis of the data is performed by a peak processing routine, calculating peak area and retention time. The network is the DEC Rr-11/REMOTE system. It operates on a PDP-11-03 with a floppy disk system for mass storage. The laboratory system has three satellites operating under it. They can utilize all of the facilities of the main computer while maintaining a minimal operational configuration. The project also had the purpose of being assimilated into Michael Starlings' data correlation system. The LSI-11 will collect data and send it to the NOVA computer system where it will be stored. The system was tested with several mixtures and the results were found to be accurate and easily obtainable,

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Chemistry
Department dc:contributor.department
Chemistry
Grantor dc:publisher
Virginia Polytechnic Institute and State University
Year dc:date.issued
1978

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Giss, Gary Neal

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/76397
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/76397

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Giss, Gary Neal. Interfacing of an LSI-11 micro processor with the spectra-physics 3500B gradient elution liquid chromatograph. masters thesis, Virginia Polytechnic Institute and State University, 1978. http://hdl.handle.net/10919/76397