Back to results

Virginia Polytechnic Institute and State University

Contamination effects in a laminar proportional amplifier

Abstract

dc:description.abstract

The effects of contaminated supply air on the performance of a laminar proportional amplifier were experimentally investigated. The air supply was contaminated with oil vapor and particulate matter. Characteristic gain curves were obtained after each stage of contamination for various loading conditions. Photographs showing the location of contaminant deposits were taken. Two inlet geometries were studied: right-angle and straightthrough. The effects of maintaining a constant pressure and constant flow rate at the inlet throughout the duration of the tests were studied. Also, aspect ratio effects. were studied. Rapid deterioration of performance was evident with the right-angle entry due to inlet blockage. By milling a cavity in the bottom cover plate, the detrimental effects of inlet blockage were delayed. With constant pressure inlet conditions and straight-through geometry, significant buildup occurred in the nozzle region and downstream. Decrease in pressure recovery was linear with time. It was determined that null shift was caused by asymmetric buildup in either the nozzle region or splitter region. With constant flow inlet conditions, the damaging effects on performance were delayed for both inlet geometries. Also, for the straight-through inlet, the nozzle region was relatively clean when compared with the constant pressure inlet case. Null shift was found to be the result of asymmetric buildup in the downstream region. At lower aspect ratios, the damaging effects of contamination were more severe and occurred in less time.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Polytechnic Institute and State University
Year dc:date.issued
1974

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rowell, Eugene Ernest, 1950-

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/76386
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/76386

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Rowell, Eugene Ernest, 1950-. Contamination effects in a laminar proportional amplifier. masters thesis, Virginia Polytechnic Institute and State University, 1974. http://hdl.handle.net/10919/76386