{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/76341"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/76341","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Analytical and experimental investigation of a flush moment end-plate connection with six bolts at the tension flange","abstract":"An analytical and experimental investigation was conducted to study the six bolt flush moment end-plate connection configuration which is used in steel frame construction. The limit states of plate yielding and bolt fracture were analyzed using yield-line theory to predict endplate thicknesses and a split-tee analogy to develop a method to predict bolt forces. Five experimental tests were conducted on four configurations within a matrix of geometric parameters. The predicted ultimate moment showed good . correlation to the yield moment obtained from the experimental deflection plots. The experimental bolt forces correlated well with the predicted bolt forces when plotted versus the applied moment. Additionally, an equation to model the moment-rotation relationship was developed from a regression analysis to determine the construction type suitable for a given connection configuration. Finally, a method of designing the six-bolt flush end-plate configuration is presented and an example given.","abstract_html":"An analytical and experimental investigation was conducted to study the six bolt flush moment end-plate connection configuration which is used in steel frame construction. The limit states of plate yielding and bolt fracture were analyzed using yield-line theory to predict endplate thicknesses and a split-tee analogy to develop a method to predict bolt forces. Five experimental tests were conducted on four configurations within a matrix of geometric parameters. The predicted ultimate moment showed good . correlation to the yield moment obtained from the experimental deflection plots. The experimental bolt forces correlated well with the predicted bolt forces when plotted versus the applied moment. Additionally, an equation to model the moment-rotation relationship was developed from a regression analysis to determine the construction type suitable for a given connection configuration. Finally, a method of designing the six-bolt flush end-plate configuration is presented and an example given.","abstract_has_math":false,"creators":["Bond, Douglas Edward"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1989,"date_issued":"1989","date_published":"1989","updated_at":"2026-07-22T22:20:02Z","subjects":[],"languages":["en_US"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/76341","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Bond, Douglas Edward"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-03-10T21:42:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-03-10T21:42:43Z"]},{"key":"dc:date.issued","label":"Date","values":["1989"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/76341"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An analytical and experimental investigation was conducted to study the six bolt flush moment end-plate connection configuration which is used in steel frame construction. The limit states of plate yielding and bolt fracture were analyzed using yield-line theory to predict endplate thicknesses and a split-tee analogy to develop a method to predict bolt forces. Five experimental tests were conducted on four configurations within a matrix of geometric parameters. The predicted ultimate moment showed good . correlation to the yield moment obtained from the experimental deflection plots. The experimental bolt forces correlated well with the predicted bolt forces when plotted versus the applied moment. Additionally, an equation to model the moment-rotation relationship was developed from a regression analysis to determine the construction type suitable for a given connection configuration. Finally, a method of designing the six-bolt flush end-plate configuration is presented and an example given."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Analytical and experimental investigation of a flush moment end-plate connection with six bolts at the tension flange"]}]}],"canonical_facts":{"dc:contributor.department":["Civil Engineering"],"dc:creator":["Bond, Douglas Edward"],"dc:date.accessioned":["2017-03-10T21:42:43Z"],"dc:date.available":["2017-03-10T21:42:43Z"],"dc:date.issued":["1989"],"dc:description.abstract":["An analytical and experimental investigation was conducted to study the six bolt flush moment end-plate connection configuration which is used in steel frame construction. The limit states of plate yielding and bolt fracture were analyzed using yield-line theory to predict endplate thicknesses and a split-tee analogy to develop a method to predict bolt forces. Five experimental tests were conducted on four configurations within a matrix of geometric parameters. The predicted ultimate moment showed good . correlation to the yield moment obtained from the experimental deflection plots. The experimental bolt forces correlated well with the predicted bolt forces when plotted versus the applied moment. Additionally, an equation to model the moment-rotation relationship was developed from a regression analysis to determine the construction type suitable for a given connection configuration. Finally, a method of designing the six-bolt flush end-plate configuration is presented and an example given."],"dc:description.degree":["Master of Science"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/76341"],"dc:language.iso":["en_US"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Analytical and experimental investigation of a flush moment end-plate connection with six bolts at the tension flange"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:02Z"}