{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/74660"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/74660","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"A capability for continuous topology transient analysis in SCR switching-mode power supplies","abstract":"A general purpose computer model for the SCR is developed. The model, consisting of both a circuit analog and parameter estimation procedure, is uniformly applicable to popular computer aided design and analysis programs such as SPICE2 and SCEPTRE. The circuit analog is based on the intrinsic three PN junction structure of the SCR and is similar to Nienhus' model. The parameter estimation procedure requires only manufacturer's specification sheet quantities as a database. It employs some of the concepts developed by Hu for a SPICE2 SCR model. This uniform model, denoted the J³ SCR model, is shown to be a useful design aid through computer simulation of fault transients which may occur in a\"Schwarz\" converter. The transients simulated would not be observable without use of a highly accurate continuous topology non-linear SCR model such as is developed here.","abstract_html":"A general purpose computer model for the SCR is developed. The model, consisting of both a circuit analog and parameter estimation procedure, is uniformly applicable to popular computer aided design and analysis programs such as SPICE2 and SCEPTRE. The circuit analog is based on the intrinsic three PN junction structure of the SCR and is similar to Nienhus&#x27; model. The parameter estimation procedure requires only manufacturer&#x27;s specification sheet quantities as a database. It employs some of the concepts developed by Hu for a SPICE2 SCR model. This uniform model, denoted the J³ SCR model, is shown to be a useful design aid through computer simulation of fault transients which may occur in a&quot;Schwarz&quot; converter. The transients simulated would not be observable without use of a highly accurate continuous topology non-linear SCR model such as is developed here.","abstract_has_math":false,"creators":["Avant, Roger Lonzo"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Lee, Fred"],"committee_members":["Chen, D.D.","Burton, Larry C.","Grigsby, L.L.","Johnson, Lee W."],"year":1983,"date_issued":"1983","date_published":"1983","updated_at":"2026-07-22T22:19:26Z","subjects":[],"languages":["en_US"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/74660","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Lee, Fred"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Chen, D.D.","Burton, Larry C.","Grigsby, L.L.","Johnson, Lee W."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Avant, Roger Lonzo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-01-30T21:23:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-01-30T21:23:33Z"]},{"key":"dc:date.issued","label":"Date","values":["1983"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/74660"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A general purpose computer model for the SCR is developed. The model, consisting of both a circuit analog and parameter estimation procedure, is uniformly applicable to popular computer aided design and analysis programs such as SPICE2 and SCEPTRE. The circuit analog is based on the intrinsic three PN junction structure of the SCR and is similar to Nienhus' model. The parameter estimation procedure requires only manufacturer's specification sheet quantities as a database. It employs some of the concepts developed by Hu for a SPICE2 SCR model. This uniform model, denoted the J³ SCR model, is shown to be a useful design aid through computer simulation of fault transients which may occur in a\"Schwarz\" converter. The transients simulated would not be observable without use of a highly accurate continuous topology non-linear SCR model such as is developed here."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A capability for continuous topology transient analysis in SCR switching-mode power supplies"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Lee, Fred"],"dc:contributor.committeemember":["Chen, D.D.","Burton, Larry C.","Grigsby, L.L.","Johnson, Lee W."],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Avant, Roger Lonzo"],"dc:date.accessioned":["2017-01-30T21:23:33Z"],"dc:date.available":["2017-01-30T21:23:33Z"],"dc:date.issued":["1983"],"dc:description.abstract":["A general purpose computer model for the SCR is developed. The model, consisting of both a circuit analog and parameter estimation procedure, is uniformly applicable to popular computer aided design and analysis programs such as SPICE2 and SCEPTRE. The circuit analog is based on the intrinsic three PN junction structure of the SCR and is similar to Nienhus' model. The parameter estimation procedure requires only manufacturer's specification sheet quantities as a database. It employs some of the concepts developed by Hu for a SPICE2 SCR model. This uniform model, denoted the J³ SCR model, is shown to be a useful design aid through computer simulation of fault transients which may occur in a\"Schwarz\" converter. The transients simulated would not be observable without use of a highly accurate continuous topology non-linear SCR model such as is developed here."],"dc:description.degree":["Ph. D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/74660"],"dc:language.iso":["en_US"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["A capability for continuous topology transient analysis in SCR switching-mode power supplies"],"dc:type":["Dissertation"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:26Z"}