{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/71331"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/71331","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Development of Adapted Capacitance Manometer for Thermospheric Applications","abstract":"An adapted capacitance manometer is a sensor composed of one fixed plate and one movable plate that is able to make accurate pressure measurements in a low pressure environment. Using detection circuitry, a change in capacitance between the two plates can be measured and correlated to a differential pressure. First, a high sensitivity manometer is produced that exhibits a measurable change in capacitance when experiencing a pressure differential in a low pressure space environment. Second, an accurate and precise detection circuit is identified to measure the change in capacitance. Both, the manometer and the detection circuitry, are tested separately and together to confirm accurate measurements when experiencing small pressure differentials. The manometer shows low sensitivity at the desired differential pressure range but reacts predictably when compared to simulations. The manometer also shows an unexpected correlation in capacitance change to temperature change.","abstract_html":"An adapted capacitance manometer is a sensor composed of one fixed plate and one movable plate that is able to make accurate pressure measurements in a low pressure environment. Using detection circuitry, a change in capacitance between the two plates can be measured and correlated to a differential pressure. First, a high sensitivity manometer is produced that exhibits a measurable change in capacitance when experiencing a pressure differential in a low pressure space environment. Second, an accurate and precise detection circuit is identified to measure the change in capacitance. Both, the manometer and the detection circuitry, are tested separately and together to confirm accurate measurements when experiencing small pressure differentials. The manometer shows low sensitivity at the desired differential pressure range but reacts predictably when compared to simulations. The manometer also shows an unexpected correlation in capacitance change to temperature change.","abstract_has_math":false,"creators":["Orr, Cameron Scott"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Earle, Gregory D."],"committee_members":["Sable, Daniel M.","Sweeney, Dennis G."],"year":2016,"date_issued":"2016-06-08","date_published":"2016-06-08","updated_at":"2026-07-22T22:18:47Z","subjects":["Capacitance Manometer","Instrument Development","Space Instrumentation","Pressure Instrument","Vacuum Testing"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:7927"],"render_values":[{"text":"vt_gsexam:7927","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/71331","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Earle, Gregory D."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sable, Daniel M.","Sweeney, Dennis G."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Orr, Cameron Scott"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-06-09T08:01:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-06-09T08:01:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-06-08"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Capacitance Manometer","Instrument Development","Space Instrumentation","Pressure Instrument","Vacuum Testing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:7927"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/71331"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An adapted capacitance manometer is a sensor composed of one fixed plate and one movable plate that is able to make accurate pressure measurements in a low pressure environment. Using detection circuitry, a change in capacitance between the two plates can be measured and correlated to a differential pressure. First, a high sensitivity manometer is produced that exhibits a measurable change in capacitance when experiencing a pressure differential in a low pressure space environment. Second, an accurate and precise detection circuit is identified to measure the change in capacitance. Both, the manometer and the detection circuitry, are tested separately and together to confirm accurate measurements when experiencing small pressure differentials. The manometer shows low sensitivity at the desired differential pressure range but reacts predictably when compared to simulations. The manometer also shows an unexpected correlation in capacitance change to temperature change."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Development of Adapted Capacitance Manometer for Thermospheric Applications"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Earle, Gregory D."],"dc:contributor.committeemember":["Sable, Daniel M.","Sweeney, Dennis G."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Orr, Cameron Scott"],"dc:date.accessioned":["2016-06-09T08:01:29Z"],"dc:date.available":["2016-06-09T08:01:29Z"],"dc:date.issued":["2016-06-08"],"dc:description.abstract":["An adapted capacitance manometer is a sensor composed of one fixed plate and one movable plate that is able to make accurate pressure measurements in a low pressure environment. Using detection circuitry, a change in capacitance between the two plates can be measured and correlated to a differential pressure. First, a high sensitivity manometer is produced that exhibits a measurable change in capacitance when experiencing a pressure differential in a low pressure space environment. Second, an accurate and precise detection circuit is identified to measure the change in capacitance. Both, the manometer and the detection circuitry, are tested separately and together to confirm accurate measurements when experiencing small pressure differentials. The manometer shows low sensitivity at the desired differential pressure range but reacts predictably when compared to simulations. The manometer also shows an unexpected correlation in capacitance change to temperature change."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:7927"],"dc:identifier.uri":["http://hdl.handle.net/10919/71331"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Capacitance Manometer","Instrument Development","Space Instrumentation","Pressure Instrument","Vacuum Testing"],"dc:title":["Development of Adapted Capacitance Manometer for Thermospheric Applications"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:18:47Z"}