Virginia Polytechnic Institute
Discharge coefficients for broad-crested weirs of low aspect ratios
Abstract
dc:description.abstractA previously developed theoretical analysis of the discharge coefficient for broad-crested weirs is investigated. Experimentally determined discharge coefficients are presented for a broad-crested weir of small crest width in an attempt to verify the theory, and an investigation of the geometry of the weir crest separation zone using a flow visualization technique is reported. Data from the literature for broad-crested weirs of large crest widths are also analyzed for comparison with the theory. Correlation between the experimental coefficients and the theory is not evident and the geometry of the crest separation zone is not observed to conform to that assumed by the theory. Probable reasons for the failure of the theory are discussed and variables which should be included in further investigation are indicated.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Civil Engineering
- Department dc:contributor.department
- Civil Engineering
- Grantor dc:publisher
- Virginia Polytechnic Institute
- Year dc:date.issued
- 1967
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Anderson, Carl
Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/10919/70485
- OAI identifier oai:identifier
- oai:vtechworks.lib.vt.edu:10919/70485