Back to results

Virginia Tech

Redundancy Evaluation of Fracture Critical Bridges

Abstract

dc:description.abstract

Cases of brittle fractures in major bridges prompted AASHTO to publish its first fracture control plan in 1978. It focused on material and fabrication standards, and required periodic 24-month hands-on inspection of bridges with fracture critical members. The practical result of this plan was to significantly increase the life cycle cost of these bridges, rendering them uneconomical. Apart from the Point Pleasant Bridge that failed in 1967, no other bridge has collapsed in the USA following a fracture, even though large fractures have been observed in many other bridges. All these bridges showed some degree of redundancy and therefore could be reclassified as non-fracture critical if detailed analyses are carried out. The goal of this study is to provide guidance on redundancy evaluation of fracture critical bridges, specifically three girder bridges and twin box-girder bridges. The effect of various loading, analysis and geometric parameters on the post fracture response and the remaining load carrying capacity of the damaged bridge is evaluated through nonlinear finite element analysis of two well-documented structures: the Hoan Bridge and the twin box-girder bridge. Parameters such as damping definition, modelling of composite action, modelling of secondary elements, boundary conditions, and rate dependent material properties are found to be crucial in capturing the bridge response. A two-step methodology for system redundancy analysis of fracture critical bridges is proposed, leading to a reclassification of these elements as non-fracture critical for in-service inspection. The first step evaluates bridge capacity to withstand collapse following fracture based on whether the residual deformation is perceivable to people on or off the bridge. If the bridge satisfies the first step requirements, then the reserve load carrying capacity of the damaged bridge is evaluated in the second step. The Hoan Bridge failed to satisfy the proposed requirements in the first step and therefore its girders could not be reclassified as non-fracture critical. The twin box-girder bridge successfully resisted the collapse in two out three loading scenarios and displayed reserve load carrying capacity following full depth fracture in the exterior girder, and therefore can be reclassified as non-fracture critical for in-service inspection.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil and Environmental Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bapat, Amey Vivek
Chairs dc:contributor.committeechair
  • Leon, Roberto T.
  • Wright, William J.
Committee members dc:contributor.committeemember
  • Charney, Finley A.
  • Roberts-Wollmann, Carin L.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:3718
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/64984

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Bapat, Amey Vivek. Redundancy Evaluation of Fracture Critical Bridges. doctoral thesis, Virginia Tech, 2014. http://hdl.handle.net/10919/64984