Back to results

Virginia Tech

Performance Analysis of an Urban Stormwater Best Management Practice Retrofit

Abstract

dc:description.abstract

Historically, the primary objective of traditional stormwater best management practices (BMPs) was to attenuate peak runoff discharges from urban areas. There has been growing demand to construct BMPs that improve stormwater runoff quality to reduce pollutant loading into downstream water bodies. A BMP located in Herndon, Virginia was retrofitted in 2009. Previously a dry detention pond, the new BMP design contains permanent wet pools as well as elements of Low Impact Development practices. A performance analysis was conducted on the retrofit to determine if the BMP was removing pollutants from stormwater runoff. Two mass-based methods were utilized for the performance analysis: the Summation of Loads Method and Effluent Probability Method. The Kaplan-Meier method and Robust Regression on ordered statistics (ROS) were used to make it possible to include censored datasets in the analysis. Analysis with the SOL method showed removal of suspended sediment, nitrogen, iron, and copper. Export of dissolved solids, phosphorus, organic carbon, and manganese was observed. The results of the Effluent Probability Method showed statistically significant reductions of sediment, iron, and copper across the entire range of monitored storm event sizes (p-value≤0.05). There was no statistical difference between the influent and effluent loads of nitrogen. Negative performance of dissolved solids, phosphorus, organic carbon, and manganese were observed for the entire range of monitored storm event sizes. The results of both methods indicated that the BMP retrofit is effectively removing sediment but failing to achieve significant nutrient reductions. This may be due to the creation of anoxic conditions from the oxygen demand of the micropool sediments and microbial degradation of vegetation within the BMP. Removal of the sediment bed and harvesting of the vegetation would likely improve the performance of the BMP.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Environmental Engineering
Department dc:contributor.department
Civil and Environmental Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Simko, Andrew Jack
Chair dc:contributor.committeechair
  • Grizzard, Thomas J.
Committee members dc:contributor.committeemember
  • Godrej, Adil N.
  • Moglen, Glenn Emery

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:3668
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/64931

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Simko, Andrew Jack. Performance Analysis of an Urban Stormwater Best Management Practice Retrofit. masters thesis, Virginia Tech, 2014. http://hdl.handle.net/10919/64931