{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/54450"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/54450","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Fourier transform infrared spectrometric detection of chromatographic effluents: instrumental and methodological improvements using a flow cell interface","abstract":"The Fourier Transform Infrared spectrometer (FTIR) has been used increasingly as a detector for various forms of chromatography. Clearly the most established marriage has been that of the Gas Chromatograph (GC) with the FTIR. GC-FTIR has been developed well beyond other forms. The main objective of this thesis, however, is to extend the FTIR as a detector to previously untested forms of chromatography using a flow cell interface. These forms of chromatography include High Performance Liquid Chromatography (HPLC), both normal-phase and reversed-phase, and packed-column Supercritical Fluid Chromatography (SFC). Normal phase HPLC-FTIR was demonstrated on not only analytical scale columns, but semi-preparative and microbore scales as well. Significant advantages, particularly with respect to the low solvent consumption, were found in the microbore HPLC-FTIR experiment. This led to the development of a chromatographically improved flow cell, the Zero Dead Volume (ZDV) HPLC-FTIR interface. The ZDV cell shows superior chromatographic characteristics and has unique spectrometric characteristics because of its unusual cross-section. Detection limits as low as 40 ng were observed. Extension to reversed-phase HPLC-FTIR required incorporation of the Flow Injection Analysis (FIA) technique of low-dispersion flowing extraction. The compounds separated by HPLC are extracted into an infrared-transparent solvent, and the extracted compounds are detected by similar means to normal-phase HPLC-FTIR. Investigation of SFC-FTIR incorporated a high-pressure, gold-lined lightpipe flow cell to detect the components separated by the supercritical C0₂/packed-column chromatograph. Several unusual spectrometric characteristics were noted. Detection limits as low as 50 ng were observed with SFC-FTIR.","abstract_html":"The Fourier Transform Infrared spectrometer (FTIR) has been used increasingly as a detector for various forms of chromatography. Clearly the most established marriage has been that of the Gas Chromatograph (GC) with the FTIR. GC-FTIR has been developed well beyond other forms. The main objective of this thesis, however, is to extend the FTIR as a detector to previously untested forms of chromatography using a flow cell interface. These forms of chromatography include High Performance Liquid Chromatography (HPLC), both normal-phase and reversed-phase, and packed-column Supercritical Fluid Chromatography (SFC). Normal phase HPLC-FTIR was demonstrated on not only analytical scale columns, but semi-preparative and microbore scales as well. Significant advantages, particularly with respect to the low solvent consumption, were found in the microbore HPLC-FTIR experiment. This led to the development of a chromatographically improved flow cell, the Zero Dead Volume (ZDV) HPLC-FTIR interface. The ZDV cell shows superior chromatographic characteristics and has unique spectrometric characteristics because of its unusual cross-section. Detection limits as low as 40 ng were observed. Extension to reversed-phase HPLC-FTIR required incorporation of the Flow Injection Analysis (FIA) technique of low-dispersion flowing extraction. The compounds separated by HPLC are extracted into an infrared-transparent solvent, and the extracted compounds are detected by similar means to normal-phase HPLC-FTIR. Investigation of SFC-FTIR incorporated a high-pressure, gold-lined lightpipe flow cell to detect the components separated by the supercritical C0₂/packed-column chromatograph. Several unusual spectrometric characteristics were noted. Detection limits as low as 50 ng were observed with SFC-FTIR.","abstract_has_math":false,"creators":["Johnson, Charles Clifford"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Chemistry","degree_department":"Chemistry","school":null,"contributors":[],"advisors":[],"committee_chairs":["Taylor, Larry T."],"committee_members":["Dorn, Harry C.","Bell, Harold M.","Graybeal, Jack D.","Dillard, John G.","McNair, Harold M."],"year":1985,"date_issued":"1985","date_published":"1985","updated_at":"2026-07-22T22:18:53Z","subjects":[],"languages":["en_US"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/54450","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Taylor, Larry T."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Dorn, Harry C.","Bell, Harold M.","Graybeal, Jack D.","Dillard, John G.","McNair, Harold M."]},{"key":"dc:contributor.department","label":"Department","values":["Chemistry"]},{"key":"dc:creator","label":"Author","values":["Johnson, Charles Clifford"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-07-10T20:00:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-07-10T20:00:08Z"]},{"key":"dc:date.issued","label":"Date","values":["1985"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/54450"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Fourier Transform Infrared spectrometer (FTIR) has been used increasingly as a detector for various forms of chromatography. Clearly the most established marriage has been that of the Gas Chromatograph (GC) with the FTIR. GC-FTIR has been developed well beyond other forms. The main objective of this thesis, however, is to extend the FTIR as a detector to previously untested forms of chromatography using a flow cell interface. These forms of chromatography include High Performance Liquid Chromatography (HPLC), both normal-phase and reversed-phase, and packed-column Supercritical Fluid Chromatography (SFC). Normal phase HPLC-FTIR was demonstrated on not only analytical scale columns, but semi-preparative and microbore scales as well. Significant advantages, particularly with respect to the low solvent consumption, were found in the microbore HPLC-FTIR experiment. This led to the development of a chromatographically improved flow cell, the Zero Dead Volume (ZDV) HPLC-FTIR interface. The ZDV cell shows superior chromatographic characteristics and has unique spectrometric characteristics because of its unusual cross-section. Detection limits as low as 40 ng were observed. Extension to reversed-phase HPLC-FTIR required incorporation of the Flow Injection Analysis (FIA) technique of low-dispersion flowing extraction. The compounds separated by HPLC are extracted into an infrared-transparent solvent, and the extracted compounds are detected by similar means to normal-phase HPLC-FTIR. Investigation of SFC-FTIR incorporated a high-pressure, gold-lined lightpipe flow cell to detect the components separated by the supercritical C0₂/packed-column chromatograph. Several unusual spectrometric characteristics were noted. Detection limits as low as 50 ng were observed with SFC-FTIR."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Fourier transform infrared spectrometric detection of chromatographic effluents: instrumental and methodological improvements using a flow cell interface"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Taylor, Larry T."],"dc:contributor.committeemember":["Dorn, Harry C.","Bell, Harold M.","Graybeal, Jack D.","Dillard, John G.","McNair, Harold M."],"dc:contributor.department":["Chemistry"],"dc:creator":["Johnson, Charles Clifford"],"dc:date.accessioned":["2015-07-10T20:00:08Z"],"dc:date.available":["2015-07-10T20:00:08Z"],"dc:date.issued":["1985"],"dc:description.abstract":["The Fourier Transform Infrared spectrometer (FTIR) has been used increasingly as a detector for various forms of chromatography. Clearly the most established marriage has been that of the Gas Chromatograph (GC) with the FTIR. GC-FTIR has been developed well beyond other forms. The main objective of this thesis, however, is to extend the FTIR as a detector to previously untested forms of chromatography using a flow cell interface. These forms of chromatography include High Performance Liquid Chromatography (HPLC), both normal-phase and reversed-phase, and packed-column Supercritical Fluid Chromatography (SFC). Normal phase HPLC-FTIR was demonstrated on not only analytical scale columns, but semi-preparative and microbore scales as well. Significant advantages, particularly with respect to the low solvent consumption, were found in the microbore HPLC-FTIR experiment. This led to the development of a chromatographically improved flow cell, the Zero Dead Volume (ZDV) HPLC-FTIR interface. The ZDV cell shows superior chromatographic characteristics and has unique spectrometric characteristics because of its unusual cross-section. Detection limits as low as 40 ng were observed. Extension to reversed-phase HPLC-FTIR required incorporation of the Flow Injection Analysis (FIA) technique of low-dispersion flowing extraction. The compounds separated by HPLC are extracted into an infrared-transparent solvent, and the extracted compounds are detected by similar means to normal-phase HPLC-FTIR. Investigation of SFC-FTIR incorporated a high-pressure, gold-lined lightpipe flow cell to detect the components separated by the supercritical C0₂/packed-column chromatograph. Several unusual spectrometric characteristics were noted. Detection limits as low as 50 ng were observed with SFC-FTIR."],"dc:description.degree":["Ph. D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/54450"],"dc:language.iso":["en_US"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Fourier transform infrared spectrometric detection of chromatographic effluents: instrumental and methodological improvements using a flow cell interface"],"dc:type":["Dissertation"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:18:53Z"}