Virginia Polytechnic Institute and State University
Freeze-thaw durability of high strength silica fume concrete
Abstract
dc:description.abstractSpecimens from 27 batches of concrete with water to cementitious (cement plus silica fume) ratio of 0.25 to 0.32, with and without entrained air, were tested for freeze-thaw durability in accordance with ASTM C666, procedure A (freezing and thawing in water). In addition, another set of similar specimens were moist cured for 28 days instead of 14 days and tested in accordance with ASTM C666 , Procedure A to determine the effect of curing time on the freeze-thaw durability of high strength concrete. Results show that non air-entrained high strength concrete with water cementitious ratio of less than 0.30, regardless of the length of curing time, is frost resistant. Non-air-entrained concrete with water-cement ratio of 0.32 is also durable if silica fume is not used.
Degree
thesis:*- Name thesis:degree_name
- Ph. D.
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Civil Engineering
- Department dc:contributor.department
- Civil Engineering
- Grantor dc:publisher
- Virginia Polytechnic Institute and State University
- Year dc:date.issued
- 1988
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kashi, Mohsen Gholam-Reza
- Chair dc:contributor.committeechair
-
- Weyers, Richard E.
- Committee members dc:contributor.committeemember
-
- Walker, Richard D.
- Barker, Richard M.
- Kuppusamy, Thangavelu
- Swift, George W.
Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/10919/53942
- OAI identifier oai:identifier