{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/53046"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/53046","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The development of a computer program using a modified room acoustics approach to determine sound levels in regular rooms","abstract":"A program was developed which calculated sound pressure levels at an array of points in a room. Necessary inputs are the room dimensions, sound power or sound pressure levels for the sources, absorption coefficients for the room surfaces, the temperature, relative humidity, and if sound pressure levels are given for the source a description of the room in which this measurement was taken. This program allowed a maximum of twenty-five sources. Calculations were made at eleven octave bands from 16 Hz. to 16,000 Hz. and converted to dBA levels. The basis for these calculations was a modified room acoustics equations. The modifications were: a factor modifying the reverberant 1 term, continually monitoring directivity with respect to changing distance of receiver points from the source, the inclusion of air absorption on the direct term and corrections for receiver points in close proximity to room surfaces, The modification to the reverberant g term was to simulate the departure from the assumption of constant energy density in irregularly proportioned rooms. The modification when receiver points were near a room surface was simply the addition of corrections to calculated sound pressure levels.","abstract_html":"A program was developed which calculated sound pressure levels at an array of points in a room. Necessary inputs are the room dimensions, sound power or sound pressure levels for the sources, absorption coefficients for the room surfaces, the temperature, relative humidity, and if sound pressure levels are given for the source a description of the room in which this measurement was taken. This program allowed a maximum of twenty-five sources. Calculations were made at eleven octave bands from 16 Hz. to 16,000 Hz. and converted to dBA levels. The basis for these calculations was a modified room acoustics equations. The modifications were: a factor modifying the reverberant 1 term, continually monitoring directivity with respect to changing distance of receiver points from the source, the inclusion of air absorption on the direct term and corrections for receiver points in close proximity to room surfaces, The modification to the reverberant g term was to simulate the departure from the assumption of constant energy density in irregularly proportioned rooms. The modification when receiver points were near a room surface was simply the addition of corrections to calculated sound pressure levels.","abstract_has_math":false,"creators":["Thompson, James Kent"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1974,"date_issued":"1974","date_published":"1974","updated_at":"2026-07-22T22:19:09Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/53046","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Thompson, James Kent"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-06-23T19:08:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-06-23T19:08:12Z"]},{"key":"dc:date.issued","label":"Date","values":["1974"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/53046"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A program was developed which calculated sound pressure levels at an array of points in a room. Necessary inputs are the room dimensions, sound power or sound pressure levels for the sources, absorption coefficients for the room surfaces, the temperature, relative humidity, and if sound pressure levels are given for the source a description of the room in which this measurement was taken. This program allowed a maximum of twenty-five sources. Calculations were made at eleven octave bands from 16 Hz. to 16,000 Hz. and converted to dBA levels. The basis for these calculations was a modified room acoustics equations. The modifications were: a factor modifying the reverberant 1 term, continually monitoring directivity with respect to changing distance of receiver points from the source, the inclusion of air absorption on the direct term and corrections for receiver points in close proximity to room surfaces, The modification to the reverberant g term was to simulate the departure from the assumption of constant energy density in irregularly proportioned rooms. The modification when receiver points were near a room surface was simply the addition of corrections to calculated sound pressure levels."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The development of a computer program using a modified room acoustics approach to determine sound levels in regular rooms"]}]}],"canonical_facts":{"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Thompson, James Kent"],"dc:date.accessioned":["2015-06-23T19:08:12Z"],"dc:date.available":["2015-06-23T19:08:12Z"],"dc:date.issued":["1974"],"dc:description.abstract":["A program was developed which calculated sound pressure levels at an array of points in a room. Necessary inputs are the room dimensions, sound power or sound pressure levels for the sources, absorption coefficients for the room surfaces, the temperature, relative humidity, and if sound pressure levels are given for the source a description of the room in which this measurement was taken. This program allowed a maximum of twenty-five sources. Calculations were made at eleven octave bands from 16 Hz. to 16,000 Hz. and converted to dBA levels. The basis for these calculations was a modified room acoustics equations. The modifications were: a factor modifying the reverberant 1 term, continually monitoring directivity with respect to changing distance of receiver points from the source, the inclusion of air absorption on the direct term and corrections for receiver points in close proximity to room surfaces, The modification to the reverberant g term was to simulate the departure from the assumption of constant energy density in irregularly proportioned rooms. The modification when receiver points were near a room surface was simply the addition of corrections to calculated sound pressure levels."],"dc:description.degree":["Master of Science"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/53046"],"dc:language.iso":["en"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["The development of a computer program using a modified room acoustics approach to determine sound levels in regular rooms"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:09Z"}