Within the vestibular system are otolith organs, both the utricle and saccule. The primary function of these organs is to transduce linear head accelerations and static head tilts into afferent signals that are sent to the central nervous system for the utilization of image fixation, muscle posture control, and the coordination of musculoskeletal movement in dynamic body motion. The utricle of the red ear slider turtle was studied in this dissertation. The turtle's utricle is composed of several layers. The base layer contains a set of neural receptor cells, called hair cells, and supporting cells. The three layers above the base layer compose the utricle's otoconial membrane (OM) and are: 1.) a saccharide gelatinous layer, 2.) a column filament layer, and 3.) a calcite and aragonite otoconial crystal layer. The primary goal of this research was to study the dynamic response of the turtle's OM to a variety of natural inertial stimuli in order to characterize its inherent mechanical properties of natural frequency ("n), damping ("), and shear modulus (G). The medial-lateral (ML) and anterior-posterior (AP) anatomical axes parameters were measured for the utricle. The ML axis median with 95% confidence intervals was found to be "n = 374 (353, 396) Hz, " = 0.50 (0.47, 0.53), and G = 9.42 (8.36, 10.49) Pa. The AP axis median with 95% confidence intervals was found to be "n = 409 (390, 430) Hz, " = 0.53 (0.48, 0.57), and G = 11.31 (10.21, 12.41). Nonlinearites were not found to occur in the OM for the tested inertial stimuli and no significant difference was found between the mechanical properties for the ML and AP axes. Additionally, this research presents the initial steps to form a novel bio-inspired accelerometer based on the morphology of the utricle. The primary transducer element for this possible otolith organ inspired accelerometer design is a droplet interface bilayer (DIB). A DIB is a lipid bilayer that is formed when the interface of two aqueous droplets, that contain free-floating lipids, are joined. The aqueous droplets are suspended in a nonpolar environment (oil) and the oil/water interface forms a lipid monolayer. This research developed and used an experimental test setup to characterize the mechanoelectrical characteristics of a micron-sized DIB. This information, along with examples in the text, could be used to further design the aforementioned accelerometer.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Department dc:contributor.department
Biomedical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dunlap, Myles Derrick
Chair dc:contributor.committeechair
  • Grant, John Wallace
Committee members dc:contributor.committeemember
  • Wicks, Alfred L.
  • Wyatt, Chris L.
  • Gabler, Hampton Clay
  • Peterson, Ellengene H.
  • Leo, Donald J.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:1025
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/52862

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Dunlap, Myles Derrick. Experimental Measurement of the Utricle's Dynamic Response and the Mechanoelectrical Characterization of a Micron-Sized DIB. doctoral thesis, Virginia Tech, 2013. http://hdl.handle.net/10919/52862