{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/52584"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/52584","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Multi-Phase Smart Converter for PV System","abstract":"Recent research and industrial accomplishment has revealed the advantages of cascaded smart converter PV system over traditional centralized and string PV system. However, even by adopting the cascaded smart converter, it is not always possible to track maximum power point (MPP) for all the panels under heavy shading condition, and a central converter is still required to track the peak power point of PV array. Based on the analysis of system configurations for smart converter PV system, an alternative PV system configuration is introduced which can extract peak power from all the panels under different mismatch condition and connect PV array to 380V DC bus without central converter. Based on this alternative PV system configuration, a multi-phase smart converter with single controller is proposed as a low cost panel-level MPPT solution. This proposal can largely reduce cost by saving MPPT controllers, current and voltage sensors without sacrificing energy production. The effectiveness of the proposal has been verified by both simulation and experiment results.","abstract_html":"Recent research and industrial accomplishment has revealed the advantages of cascaded smart converter PV system over traditional centralized and string PV system. However, even by adopting the cascaded smart converter, it is not always possible to track maximum power point (MPP) for all the panels under heavy shading condition, and a central converter is still required to track the peak power point of PV array. Based on the analysis of system configurations for smart converter PV system, an alternative PV system configuration is introduced which can extract peak power from all the panels under different mismatch condition and connect PV array to 380V DC bus without central converter. Based on this alternative PV system configuration, a multi-phase smart converter with single controller is proposed as a low cost panel-level MPPT solution. This proposal can largely reduce cost by saving MPPT controllers, current and voltage sensors without sacrificing energy production. The effectiveness of the proposal has been verified by both simulation and experiment results.","abstract_has_math":false,"creators":["Cao, Zhongsheng"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Li, Qiang"],"committee_members":["Lee, Fred C.","Guido, Louis J."],"year":2014,"date_issued":"2014-10-02","date_published":"2014-10-02","updated_at":"2026-07-22T22:20:08Z","subjects":["PV panel","MPPT","smart converter","multi-phase converter"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:3686"],"render_values":[{"text":"vt_gsexam:3686","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/52584","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Li, Qiang"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lee, Fred C.","Guido, Louis J."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Cao, Zhongsheng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-05-23T08:09:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-05-23T08:09:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-10-02"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["PV panel","MPPT","smart converter","multi-phase converter"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:3686"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/52584"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Recent research and industrial accomplishment has revealed the advantages of cascaded smart converter PV system over traditional centralized and string PV system. However, even by adopting the cascaded smart converter, it is not always possible to track maximum power point (MPP) for all the panels under heavy shading condition, and a central converter is still required to track the peak power point of PV array. Based on the analysis of system configurations for smart converter PV system, an alternative PV system configuration is introduced which can extract peak power from all the panels under different mismatch condition and connect PV array to 380V DC bus without central converter. Based on this alternative PV system configuration, a multi-phase smart converter with single controller is proposed as a low cost panel-level MPPT solution. This proposal can largely reduce cost by saving MPPT controllers, current and voltage sensors without sacrificing energy production. The effectiveness of the proposal has been verified by both simulation and experiment results."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Multi-Phase Smart Converter for PV System"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Li, Qiang"],"dc:contributor.committeemember":["Lee, Fred C.","Guido, Louis J."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Cao, Zhongsheng"],"dc:date.accessioned":["2015-05-23T08:09:57Z"],"dc:date.available":["2015-05-23T08:09:57Z"],"dc:date.issued":["2014-10-02"],"dc:description.abstract":["Recent research and industrial accomplishment has revealed the advantages of cascaded smart converter PV system over traditional centralized and string PV system. However, even by adopting the cascaded smart converter, it is not always possible to track maximum power point (MPP) for all the panels under heavy shading condition, and a central converter is still required to track the peak power point of PV array. Based on the analysis of system configurations for smart converter PV system, an alternative PV system configuration is introduced which can extract peak power from all the panels under different mismatch condition and connect PV array to 380V DC bus without central converter. Based on this alternative PV system configuration, a multi-phase smart converter with single controller is proposed as a low cost panel-level MPPT solution. This proposal can largely reduce cost by saving MPPT controllers, current and voltage sensors without sacrificing energy production. The effectiveness of the proposal has been verified by both simulation and experiment results."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:3686"],"dc:identifier.uri":["http://hdl.handle.net/10919/52584"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["PV panel","MPPT","smart converter","multi-phase converter"],"dc:title":["Multi-Phase Smart Converter for PV System"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:08Z"}