{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/51611"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/51611","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"An Open Loop Feed-Forward Control Scheme for Bioinspired Artificial Hair Cell Sensors","abstract":"This research documents the creation and use of an open-loop feed forward control scheme designed to manipulate the DC potential across lipid bilayer membranes in artificial hair cell sensors. Inspired by the human cochlea's non-linear gain phenomenon, whereby the cochlea can increase or decrease the effective gain of the auditory system, this controller is the first step in developing more sophisticated signal processing schemes for use with future bio-inspired artificial hair cell development. This open-loop controller allows for three preset gain mappings to tailor the DC offset in response to an external stimulus. Linear, nonlinear and sigmoidal mappings were created to observe the differences in system response during constant frequency and variable frequency excitation. In constant frequency testing, artificial hair cell sensors were excited at 100 Hz across a range of input intensities to observer current output response during increasing or decreasing excitation levels. Results showed average coherence values above 0.98 for the relationship between current output and fluid velocity, indicating a strong correlation between excitation and measured output. In the bilayer with stereocilia test case, RMS power increased with higher excitation levels but the various control laws did not appear to have any discernible impact on output power. In variable frequency testing, sensors were excited from 0-300 Hz to observe the real time effects of our control law on amplification or attenuation of output current with varying input intensity. Results of the variable frequency excitation could not definitively prove that the varied DC potential had an effect on current output due to excessive capacitive noise, but the controller did provide some encouraging results from its behavior during testing. We observed three distinct DC potential response curves for each mapping, indicating, that with some refinement, we should be able to manipulate output current with user defined gain tunings.","abstract_html":"This research documents the creation and use of an open-loop feed forward control scheme designed to manipulate the DC potential across lipid bilayer membranes in artificial hair cell sensors. Inspired by the human cochlea&#x27;s non-linear gain phenomenon, whereby the cochlea can increase or decrease the effective gain of the auditory system, this controller is the first step in developing more sophisticated signal processing schemes for use with future bio-inspired artificial hair cell development. This open-loop controller allows for three preset gain mappings to tailor the DC offset in response to an external stimulus. Linear, nonlinear and sigmoidal mappings were created to observe the differences in system response during constant frequency and variable frequency excitation. In constant frequency testing, artificial hair cell sensors were excited at 100 Hz across a range of input intensities to observer current output response during increasing or decreasing excitation levels. Results showed average coherence values above 0.98 for the relationship between current output and fluid velocity, indicating a strong correlation between excitation and measured output. In the bilayer with stereocilia test case, RMS power increased with higher excitation levels but the various control laws did not appear to have any discernible impact on output power. In variable frequency testing, sensors were excited from 0-300 Hz to observe the real time effects of our control law on amplification or attenuation of output current with varying input intensity. Results of the variable frequency excitation could not definitively prove that the varied DC potential had an effect on current output due to excessive capacitive noise, but the controller did provide some encouraging results from its behavior during testing. We observed three distinct DC potential response curves for each mapping, indicating, that with some refinement, we should be able to manipulate output current with user defined gain tunings.","abstract_has_math":false,"creators":["Crowley, Kevin Michael"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Leo, Donald J."],"committee_members":["Grant, John Wallace","Tarazaga, Pablo Alberto"],"year":2015,"date_issued":"2015-03-11","date_published":"2015-03-11","updated_at":"2026-07-22T22:19:41Z","subjects":["Bioinspired","Lipid Bilayer","Cochlear","Sensor","Artificial Hair Cell","Control","dSpace","Simulink"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:4668"],"render_values":[{"text":"vt_gsexam:4668","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/51611","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Leo, Donald J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Grant, John Wallace","Tarazaga, Pablo Alberto"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Crowley, Kevin Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-03-12T08:00:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-03-12T08:00:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-03-11"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bioinspired","Lipid Bilayer","Cochlear","Sensor","Artificial Hair Cell","Control","dSpace","Simulink"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:4668"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/51611"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research documents the creation and use of an open-loop feed forward control scheme designed to manipulate the DC potential across lipid bilayer membranes in artificial hair cell sensors. Inspired by the human cochlea's non-linear gain phenomenon, whereby the cochlea can increase or decrease the effective gain of the auditory system, this controller is the first step in developing more sophisticated signal processing schemes for use with future bio-inspired artificial hair cell development. This open-loop controller allows for three preset gain mappings to tailor the DC offset in response to an external stimulus. Linear, nonlinear and sigmoidal mappings were created to observe the differences in system response during constant frequency and variable frequency excitation. In constant frequency testing, artificial hair cell sensors were excited at 100 Hz across a range of input intensities to observer current output response during increasing or decreasing excitation levels. Results showed average coherence values above 0.98 for the relationship between current output and fluid velocity, indicating a strong correlation between excitation and measured output. In the bilayer with stereocilia test case, RMS power increased with higher excitation levels but the various control laws did not appear to have any discernible impact on output power. In variable frequency testing, sensors were excited from 0-300 Hz to observe the real time effects of our control law on amplification or attenuation of output current with varying input intensity. Results of the variable frequency excitation could not definitively prove that the varied DC potential had an effect on current output due to excessive capacitive noise, but the controller did provide some encouraging results from its behavior during testing. We observed three distinct DC potential response curves for each mapping, indicating, that with some refinement, we should be able to manipulate output current with user defined gain tunings."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["An Open Loop Feed-Forward Control Scheme for Bioinspired Artificial Hair Cell Sensors"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Leo, Donald J."],"dc:contributor.committeemember":["Grant, John Wallace","Tarazaga, Pablo Alberto"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Crowley, Kevin Michael"],"dc:date.accessioned":["2015-03-12T08:00:27Z"],"dc:date.available":["2015-03-12T08:00:27Z"],"dc:date.issued":["2015-03-11"],"dc:description.abstract":["This research documents the creation and use of an open-loop feed forward control scheme designed to manipulate the DC potential across lipid bilayer membranes in artificial hair cell sensors. Inspired by the human cochlea's non-linear gain phenomenon, whereby the cochlea can increase or decrease the effective gain of the auditory system, this controller is the first step in developing more sophisticated signal processing schemes for use with future bio-inspired artificial hair cell development. This open-loop controller allows for three preset gain mappings to tailor the DC offset in response to an external stimulus. Linear, nonlinear and sigmoidal mappings were created to observe the differences in system response during constant frequency and variable frequency excitation. In constant frequency testing, artificial hair cell sensors were excited at 100 Hz across a range of input intensities to observer current output response during increasing or decreasing excitation levels. Results showed average coherence values above 0.98 for the relationship between current output and fluid velocity, indicating a strong correlation between excitation and measured output. In the bilayer with stereocilia test case, RMS power increased with higher excitation levels but the various control laws did not appear to have any discernible impact on output power. In variable frequency testing, sensors were excited from 0-300 Hz to observe the real time effects of our control law on amplification or attenuation of output current with varying input intensity. Results of the variable frequency excitation could not definitively prove that the varied DC potential had an effect on current output due to excessive capacitive noise, but the controller did provide some encouraging results from its behavior during testing. We observed three distinct DC potential response curves for each mapping, indicating, that with some refinement, we should be able to manipulate output current with user defined gain tunings."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:4668"],"dc:identifier.uri":["http://hdl.handle.net/10919/51611"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Bioinspired","Lipid Bilayer","Cochlear","Sensor","Artificial Hair Cell","Control","dSpace","Simulink"],"dc:title":["An Open Loop Feed-Forward Control Scheme for Bioinspired Artificial Hair Cell Sensors"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:41Z"}