Back to results

Virginia Tech

Collimator width Optimization in X-ray Luminescent Computed Tomography

Abstract

dc:description.abstract

X-ray Luminescent Computed Tomography (XLCT) is a new imaging modality which is under extensive trials at present. The modality works by selective excitation of X-ray sensitive nanophosphors and detecting the optical signal thus generated. This system can be used towards recreating high quality tomographic slices even with low X-ray dose. There have been many studies which have reported successful validation of the underlying philosophy. However, there is still lack of information about optimal settings or combination of imaging parameters, which could yield best outputs. Research groups participating in this area have reported results on basis of dose, signal to noise ratio or resolution only. In this thesis, the candidate has evaluated XLCT taking into consideration noise and resolution in terms of composite indices. Simulations have been performed for various beam widths and noise & resolution metrics deduced. This information has been used in evaluating quality of images on basis of CT Figure of Merit & a modified Wang-Bovik Image Quality index. Simulations indicate the presence of an optimal setting which can be set prior to extensive scans. The conducted study, although focusing on a particular implementation, hopes to establish a paradigm in finding best settings for any XLCT system. Scanning with an optimal setting preconfigured can help in vastly reducing the cost and risks involved with this imaging modality.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Computer Engineering
Department dc:contributor.department
Electrical and Computer Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mishra, Sourav
Chair dc:contributor.committeechair
  • Wang, Ge
Committee members dc:contributor.committeemember
  • Xuan, Jianhua
  • Yu, Guoqiang

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:1031
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/51118

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Mishra, Sourav. Collimator width Optimization in X-ray Luminescent Computed Tomography. masters thesis, Virginia Tech, 2013. http://hdl.handle.net/10919/51118