Back to results

Virginia Polytechnic Institute and State University

Corona switching: an osmogene mitigation technique

Abstract

dc:description.abstract

Odorous gases such as hydrogen sulfide have long been associated with wastewater treatment plants, especially those with long forced mains which allow septic conditions to develop. With the encroachment of urban and suburban populations, many wastewater treatment plants are no longer located far enough from residential areas to prevent odor problems. This has lead to renewed efforts to develop odor control techniques. The application of high energy coronas as a means to oxidize odorous gases has been limited by the relatively small size of the corona region around a given charged wire, approximately 1 centimeter at an applied voltage of 35 kilovolts. Attempts to enlarge the effective corona region by spacing wires such that their coronas would overlap have failed due to corona extinction, the destructive interference of the electric fields surrounding adjacent charged wires. This study demonstrates that corona extinction can be avoided in a system of closely spaced wires flanked by grounded plates if the wires are energized individually instead of' simultaneously. By employing a rapid load-switching technique an essentially continuous corona sheet can be produced. A bench-scale device utilizing the rapid switching principle was constructed and its ability to remove odorous gases, including hydrogen sulfide, was demonstrated. The influence of parameters such as flowrate, inlet concentration, switching frequency, temperature, and humidity on removal efficiency was evaluated.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Virginia Polytechnic Institute and State University
Year dc:date.issued
1988

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Atkinson, R. Dwight
Chair dc:contributor.committeechair
  • Hughes, J. Martin
Committee members dc:contributor.committeemember
  • Chevone, Boris I.
  • Furr, A. Keith
  • Sherrard, Joseph H.
  • Wiggert, James M.

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/49920
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/49920

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Atkinson, R. Dwight. Corona switching: an osmogene mitigation technique. doctoral thesis, Virginia Polytechnic Institute and State University, 1988. http://hdl.handle.net/10919/49920