Back to results

Virginia Tech

Practical Impacts of Galvanic Corrosion in Water Service Lines and Premise Plumbing

Abstract

dc:description.abstract

There is emerging concern about the potential for elevated lead in water after water utilities conduct EPA mandated (or voluntary) partial replacements of existing lead service lines. Connections between dissimilar metals results in the accelerated corrosion of the less noble metal via galvanic attack, increasing metal concentrations in water and posing potential public health risks. Many practical problems associated with stopping galvanic attack between copper:galvanized iron and copper:lead via use of dielectrics have also been raised. Galvanic corrosion can be effectively stopped by isolating the dissimilar metals; however, completely eliminating electrical continuity may not always be practical or allowed by code. Instead, increasing separation distance between the two metals was hypothesized to considerably reduce galvanic corrosion. Galvanic corrosion and lead leaching were evaluated for lead:copper connections with varying separation distances while maintaining electrical continuity. Increased distance between lead and copper pipe dramatically reduced the galvanic current and the magnitude of lead release. Galvanized iron and copper connections were also investigated using various commercial fittings, and results verified that a controlling factor was separation distance between the two dissimilar metals. When considering the long-term behavior of partially replaced lead service lines, detrimental effects from galvanic corrosion worsened with time. Even when water was sampled consistently at moderate flow rate, the condition representing traditional partial service line replacement was 40% worse than a full lead service line. At elevated flowrates, lead concentrations and variability increased for partly replaced lead pipe versus full lead pipe due to reservoirs of lead rust formed via galvanic corrosion. At low flowrates, these negative impacts were not observed. Finally, crevices formed by the use of commercial couplings increased lead release. Overall, the results enhance practical understanding of galvanic corrosion impacts and use of dielectrics in water service lines and premise plumbing.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil and Environmental Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • StClair, Justin Monroe
Chair dc:contributor.committeechair
  • Edwards, Marc A.
Committee members dc:contributor.committeemember
  • Sinha, Sunil Kumar
  • Sarver, Emily A.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:146
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/49583

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

StClair, Justin Monroe. Practical Impacts of Galvanic Corrosion in Water Service Lines and Premise Plumbing. masters thesis, Virginia Tech, 2013. http://hdl.handle.net/10919/49583