Back to results

Virginia Tech

Performance Evaluation of a Low Impact Development Retrofit for Urban Stormwater Treatment

Abstract

dc:description.abstract

The goal of Low Impact Development (LID) is to mimic the pre-development hydrologic regime of a catchment through infiltration, filtration, storage, evaporation, and detention of post-development runoff using small-scale hydrologic controls close to the source. A LID facility located in Northern Virginia was examined for pollutant removal and hydrologic performance. The treatment train included four in-line grass swales followed by a bioretention cell with a gravel base. The facility retained 85% of the rainfall. Influent and effluent pollutant loads were calculated using three common substitution methods for datasets censored by values below the analytical detection limit. The Summation of Loads (SOL) method was used to facilitate understanding of how data censoring affected performance results when substitution methods were used. The SOL analysis showed positive removal performance for most nutrient species, sediment, oxygen demanding substances, selected trace metals and total petroleum hydrocarbons. Negative performance was observed for oxidized nitrogen, total dissolved solids and oil & grease. LID facility influent and effluent loads were also compared using the Effluent Probability Method (EPM). The EPM analysis showed statistically significant (p d 0.05) pollutant load removal performance over the entire range of sampled events for total suspended solids, total phosphorus, total nitrogen, total Kjeldahl nitrogen, ammonia nitrogen, chemical oxygen demand, copper, zinc and alkalinity. EPM analysis did not show significant removals of oxidized nitrogen, total dissolved solids, orthophosphate phosphorus and hardness.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Environmental Engineering
Department dc:contributor.department
Civil and Environmental Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Le Bel, Paul David
Chair dc:contributor.committeechair
  • Grizzard, Thomas J.
Committee members dc:contributor.committeemember
  • Godrej, Adil N.
  • Sample, David J.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:683
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/48656

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Le Bel, Paul David. Performance Evaluation of a Low Impact Development Retrofit for Urban Stormwater Treatment. masters thesis, Virginia Tech, 2013. http://hdl.handle.net/10919/48656