{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/47675"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/47675","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Machine Learning-Based Parameter Validation","abstract":"As power system grids continue to grow in order to support an increasing energy demand, the system's behavior accordingly evolves, continuing to challenge designs for maintaining security. It has become apparent in the past few years that, as much as discovering vulnerabilities in the power network, accurate simulations are very critical. This study explores a classification method for validating simulation models, using disturbance measurements from phasor measurement units (PMU). The technique used employs the Random Forest learning algorithm to find a correlation between specific model parameter changes, and the variations in the dynamic response. Also, the measurements used for building and evaluating the classifiers were characterized using Prony decomposition. The generator model, consisting of an exciter, governor, and its standard parameters have been validated using short circuit faults. Single-error classifiers were first tested, where the accuracies of the classifiers built using positive, negative, and zero sequence measurements were compared. The negative sequence measurements have consistently produced the best classifiers, with majority of the parameter classes attaining F-measure accuracies greater than 90%. A multiple-parameter error technique for validation has also been developed and tested on standard generator parameters. Only a few target parameter classes had good accuracies in the presence of multiple parameter errors, but the results were enough to permit a sequential process of validation, where elimination of a highly detectable error can improve the accuracy of suspect errors dependent on the former's removal, and continuing the procedure until all corrections are covered.","abstract_html":"As power system grids continue to grow in order to support an increasing energy demand, the system&#x27;s behavior accordingly evolves, continuing to challenge designs for maintaining security. It has become apparent in the past few years that, as much as discovering vulnerabilities in the power network, accurate simulations are very critical. This study explores a classification method for validating simulation models, using disturbance measurements from phasor measurement units (PMU). The technique used employs the Random Forest learning algorithm to find a correlation between specific model parameter changes, and the variations in the dynamic response. Also, the measurements used for building and evaluating the classifiers were characterized using Prony decomposition. The generator model, consisting of an exciter, governor, and its standard parameters have been validated using short circuit faults. Single-error classifiers were first tested, where the accuracies of the classifiers built using positive, negative, and zero sequence measurements were compared. The negative sequence measurements have consistently produced the best classifiers, with majority of the parameter classes attaining F-measure accuracies greater than 90%. A multiple-parameter error technique for validation has also been developed and tested on standard generator parameters. Only a few target parameter classes had good accuracies in the presence of multiple parameter errors, but the results were enough to permit a sequential process of validation, where elimination of a highly detectable error can improve the accuracy of suspect errors dependent on the former&#x27;s removal, and continuing the procedure until all corrections are covered.","abstract_has_math":false,"creators":["Badayos, Noah Garcia"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Centeno, Virgilio A."],"committee_members":["Phadke, Arun G.","Evrenosoglu, Cansin Yaman","De La Ree, Jaime","Ramakrishnan, Naren","Shukla, Sandeep K."],"year":2014,"date_issued":"2014-04-24","date_published":"2014-04-24","updated_at":"2026-07-22T22:20:07Z","subjects":["power systems","model validation","Machine learning","data mining","random forest","Prony analysis","phasor measurement units"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:2698"],"render_values":[{"text":"vt_gsexam:2698","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/47675","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Centeno, Virgilio A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Phadke, Arun G.","Evrenosoglu, Cansin Yaman","De La Ree, Jaime","Ramakrishnan, Naren","Shukla, Sandeep K."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Badayos, Noah Garcia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-04-25T08:00:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-04-25T08:00:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-04-24"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["power systems","model validation","Machine learning","data mining","random forest","Prony analysis","phasor measurement units"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:2698"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/47675"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["As power system grids continue to grow in order to support an increasing energy demand, the system's behavior accordingly evolves, continuing to challenge designs for maintaining security. It has become apparent in the past few years that, as much as discovering vulnerabilities in the power network, accurate simulations are very critical. This study explores a classification method for validating simulation models, using disturbance measurements from phasor measurement units (PMU). The technique used employs the Random Forest learning algorithm to find a correlation between specific model parameter changes, and the variations in the dynamic response. Also, the measurements used for building and evaluating the classifiers were characterized using Prony decomposition. The generator model, consisting of an exciter, governor, and its standard parameters have been validated using short circuit faults. Single-error classifiers were first tested, where the accuracies of the classifiers built using positive, negative, and zero sequence measurements were compared. The negative sequence measurements have consistently produced the best classifiers, with majority of the parameter classes attaining F-measure accuracies greater than 90%. A multiple-parameter error technique for validation has also been developed and tested on standard generator parameters. Only a few target parameter classes had good accuracies in the presence of multiple parameter errors, but the results were enough to permit a sequential process of validation, where elimination of a highly detectable error can improve the accuracy of suspect errors dependent on the former's removal, and continuing the procedure until all corrections are covered."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Machine Learning-Based Parameter Validation"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Centeno, Virgilio A."],"dc:contributor.committeemember":["Phadke, Arun G.","Evrenosoglu, Cansin Yaman","De La Ree, Jaime","Ramakrishnan, Naren","Shukla, Sandeep K."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Badayos, Noah Garcia"],"dc:date.accessioned":["2014-04-25T08:00:18Z"],"dc:date.available":["2014-04-25T08:00:18Z"],"dc:date.issued":["2014-04-24"],"dc:description.abstract":["As power system grids continue to grow in order to support an increasing energy demand, the system's behavior accordingly evolves, continuing to challenge designs for maintaining security. It has become apparent in the past few years that, as much as discovering vulnerabilities in the power network, accurate simulations are very critical. This study explores a classification method for validating simulation models, using disturbance measurements from phasor measurement units (PMU). The technique used employs the Random Forest learning algorithm to find a correlation between specific model parameter changes, and the variations in the dynamic response. Also, the measurements used for building and evaluating the classifiers were characterized using Prony decomposition. The generator model, consisting of an exciter, governor, and its standard parameters have been validated using short circuit faults. Single-error classifiers were first tested, where the accuracies of the classifiers built using positive, negative, and zero sequence measurements were compared. The negative sequence measurements have consistently produced the best classifiers, with majority of the parameter classes attaining F-measure accuracies greater than 90%. A multiple-parameter error technique for validation has also been developed and tested on standard generator parameters. Only a few target parameter classes had good accuracies in the presence of multiple parameter errors, but the results were enough to permit a sequential process of validation, where elimination of a highly detectable error can improve the accuracy of suspect errors dependent on the former's removal, and continuing the procedure until all corrections are covered."],"dc:description.degree":["Ph. D."],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:2698"],"dc:identifier.uri":["http://hdl.handle.net/10919/47675"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["power systems","model validation","Machine learning","data mining","random forest","Prony analysis","phasor measurement units"],"dc:title":["Machine Learning-Based Parameter Validation"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:07Z"}