{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/46476"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/46476","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Development of Methodologies for the Noninvasive Estimation of Blood Perfusion","abstract":"This work focuses on the development of a system to noninvasively estimate blood perfusion using thermal methods. This is accomplished by the combination of a bioprobe, biothermal model, and parameter estimation techniques. The probe consists of a heat flux sensor and surface thermocouple placed in contact with tissue while the opposite side is cooled by jets of room temperature air. The biothermal model predicts the temperature and heat flux within tissue and probe based upon the input of blood perfusion and the thermal contact resistance between probe and tissue. Parameter estimation techniques are developed that use the model to simultaneously estimate blood perfusion and contact resistance based on experimental heat flux and/or temperature. A gradient based system minimizes a sum of squares error function based on either or both heat flux and temperature. This system is tested on human forearms and in controlled flow rate experiments using tissue phantoms. Blood perfusion estimates from the controlled experiments are positively correlated with experimental flow rate. Experimental measurements and statistical analysis show distinct variations in the heat flux signal and rises in perfusion estimates with increasing flow rate. This research validates the use of thermal and parameter estimation methods to develop a practical, noninvasive probe to clinically measure blood perfusion.","abstract_html":"This work focuses on the development of a system to noninvasively estimate blood perfusion using thermal methods. This is accomplished by the combination of a bioprobe, biothermal model, and parameter estimation techniques. The probe consists of a heat flux sensor and surface thermocouple placed in contact with tissue while the opposite side is cooled by jets of room temperature air. The biothermal model predicts the temperature and heat flux within tissue and probe based upon the input of blood perfusion and the thermal contact resistance between probe and tissue. Parameter estimation techniques are developed that use the model to simultaneously estimate blood perfusion and contact resistance based on experimental heat flux and/or temperature. A gradient based system minimizes a sum of squares error function based on either or both heat flux and temperature. This system is tested on human forearms and in controlled flow rate experiments using tissue phantoms. Blood perfusion estimates from the controlled experiments are positively correlated with experimental flow rate. Experimental measurements and statistical analysis show distinct variations in the heat flux signal and rises in perfusion estimates with increasing flow rate. This research validates the use of thermal and parameter estimation methods to develop a practical, noninvasive probe to clinically measure blood perfusion.","abstract_has_math":false,"creators":["Robinson, Paul S."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Diller, Thomas E."],"committee_members":["Scott, Elaine P.","Veit, Hugo P.","Diller, Thomas E."],"year":1998,"date_issued":"1998-01-29","date_published":"1998-01-29","updated_at":"2026-07-22T22:20:08Z","subjects":["blood perfusion","biothermal modeling","biothermal heat transfer","parameter estimation","heat flux sensors"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-22398-215911"],"render_values":[{"text":"etd-22398-215911","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/46476","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Diller, Thomas E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Scott, Elaine P.","Veit, Hugo P.","Diller, Thomas E."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Robinson, Paul S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:52:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:52:52Z","1999-03-26"]},{"key":"dc:date.issued","label":"Date","values":["1998-01-29"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["blood perfusion","biothermal modeling","biothermal heat transfer","parameter estimation","heat flux sensors"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-22398-215911"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/46476"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work focuses on the development of a system to noninvasively estimate blood perfusion using thermal methods. This is accomplished by the combination of a bioprobe, biothermal model, and parameter estimation techniques. The probe consists of a heat flux sensor and surface thermocouple placed in contact with tissue while the opposite side is cooled by jets of room temperature air. The biothermal model predicts the temperature and heat flux within tissue and probe based upon the input of blood perfusion and the thermal contact resistance between probe and tissue. Parameter estimation techniques are developed that use the model to simultaneously estimate blood perfusion and contact resistance based on experimental heat flux and/or temperature. A gradient based system minimizes a sum of squares error function based on either or both heat flux and temperature. This system is tested on human forearms and in controlled flow rate experiments using tissue phantoms. Blood perfusion estimates from the controlled experiments are positively correlated with experimental flow rate. Experimental measurements and statistical analysis show distinct variations in the heat flux signal and rises in perfusion estimates with increasing flow rate. This research validates the use of thermal and parameter estimation methods to develop a practical, noninvasive probe to clinically measure blood perfusion."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["Development of Methodologies for the Noninvasive Estimation of Blood Perfusion"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Diller, Thomas E."],"dc:contributor.committeemember":["Scott, Elaine P.","Veit, Hugo P.","Diller, Thomas E."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Robinson, Paul S."],"dc:date.accessioned":["2014-03-14T21:52:52Z"],"dc:date.available":["2014-03-14T21:52:52Z","1999-03-26"],"dc:date.issued":["1998-01-29"],"dc:description.abstract":["This work focuses on the development of a system to noninvasively estimate blood perfusion using thermal methods. This is accomplished by the combination of a bioprobe, biothermal model, and parameter estimation techniques. The probe consists of a heat flux sensor and surface thermocouple placed in contact with tissue while the opposite side is cooled by jets of room temperature air. The biothermal model predicts the temperature and heat flux within tissue and probe based upon the input of blood perfusion and the thermal contact resistance between probe and tissue. Parameter estimation techniques are developed that use the model to simultaneously estimate blood perfusion and contact resistance based on experimental heat flux and/or temperature. A gradient based system minimizes a sum of squares error function based on either or both heat flux and temperature. This system is tested on human forearms and in controlled flow rate experiments using tissue phantoms. Blood perfusion estimates from the controlled experiments are positively correlated with experimental flow rate. Experimental measurements and statistical analysis show distinct variations in the heat flux signal and rises in perfusion estimates with increasing flow rate. This research validates the use of thermal and parameter estimation methods to develop a practical, noninvasive probe to clinically measure blood perfusion."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-22398-215911"],"dc:identifier.uri":["http://hdl.handle.net/10919/46476"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["blood perfusion","biothermal modeling","biothermal heat transfer","parameter estimation","heat flux sensors"],"dc:title":["Development of Methodologies for the Noninvasive Estimation of Blood Perfusion"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:08Z"}