Back to results

Virginia Tech

Investigation of the Effects of Sequential Anaerobic, Anoxic and Aerobic Zones on Dissolved Oxygen Transfer Parameters in a biological Nutrient Removal Pilot Plant

Abstract

dc:description.abstract

Bench and pilot scale determinations of the volumetric oxygen transfer coefficient, K<sub>L</sub>a, were performed on an improved A²/O biological nutrient removal (BNR) pilot plant. Effluent from a full scale primary clarifier, used as pilot plant influent, was found to have an alpha (ratio of process to clean water K<sub>L</sub>a) of 0.71 as determined in a 21 liter bench scale reactor and an alpha of 0.332 as determined in a 0.45 m³ aeration basin of the 2.4 m³ pilot plant. Alpha of a 1:1 mixture of primary clarifier effluent with pilot plant return activated sludge was determined to be 0.94 at bench scale and 0.71 at pilot scale. An assay of alphas through the initial non aerated treatment zones of the pilot plant using the bench scale reactor indicated that alphas peaked in the effluent of the first anaerobic zone (alpha equal to 1.01) and were lower in the second anaerobic zone and first anoxic zone. An assay of alphas in the three pilot plant series sideline aeration basins indicated that alpha was maximum in the first aeration basin (alpha equal to 0.905) and were lower in the second and third aeration basins (0.716 and 0.661 respectively). A consistent increase in average surface tension was noted from the first to second to third aeration basins, however the differences were not statistically significant. A comparison of pilot plant alphas determined in the first aeration basin following anaerobic nominal hydraulic retention times of 0.0, 0.21, 0.43, and 0.64 hours yielded alpha values of 0.71, 0.94, 0.64, and 0.74 respectively. Like the assay using the bench scale reactor, the alpha values at pilot scale peaked following treatment in only one anaerobic zone (nominal HRT of 0.21 hours). The study concludes that short exposures in an initial anaerobic reactor as required for biological phosphorus removal may benefit oxygen transfer efficiency through increased alphas, however the benefits of long periods of anaerobic reaction time (over 0.43 hours) are uncertain.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Environmental Planning
Department dc:contributor.department
Environmental Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1998

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nair, Arthur William
Chair dc:contributor.committeechair
  • Randall, Clifford W.
Committee members dc:contributor.committeemember
  • Little, John C.
  • Love, Nancy G.

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-121698-120457
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/46264

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Nair, Arthur William. Investigation of the Effects of Sequential Anaerobic, Anoxic and Aerobic Zones on Dissolved Oxygen Transfer Parameters in a biological Nutrient Removal Pilot Plant. masters thesis, Virginia Tech, 1998. http://hdl.handle.net/10919/46264