{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/46091"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/46091","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Unsteady surface heat flux and temperature measurements","abstract":"A fast response thin-film heat flux sensor was used to measure the time-resolved surface heat flux and temperature from a turbulent combustion flame impinging on a surface. Using the analytical semi-infinite conduction model, the unsteady surface heat flux was calculated from the transient temperature measurements and the surface temperature was calculated from the unsteady surface heat flux measurements. Methods of comparing time-resolved heat flux and temperature data were presented and discussed. The standard analytical method for converting surface temperature to heat flux was used. Two new analytical methods were developed for converting heat flux to surface temperature. The study is the first demonstration of time-resolved temperature signals generated from time-resolved heat flux measurements. The results graphically illustrate the effects of data processing on electrical noise present in the actual signal. The effect of flame unsteadiness is also shown, especially in the time-resolved heat flux measurements, which gives insight into the behavior of a propane torch. One application is for development of feed-forward control systems in industrial processes with fast transients.","abstract_html":"A fast response thin-film heat flux sensor was used to measure the time-resolved surface heat flux and temperature from a turbulent combustion flame impinging on a surface. Using the analytical semi-infinite conduction model, the unsteady surface heat flux was calculated from the transient temperature measurements and the surface temperature was calculated from the unsteady surface heat flux measurements. Methods of comparing time-resolved heat flux and temperature data were presented and discussed. The standard analytical method for converting surface temperature to heat flux was used. Two new analytical methods were developed for converting heat flux to surface temperature. The study is the first demonstration of time-resolved temperature signals generated from time-resolved heat flux measurements. The results graphically illustrate the effects of data processing on electrical noise present in the actual signal. The effect of flame unsteadiness is also shown, especially in the time-resolved heat flux measurements, which gives insight into the behavior of a propane torch. One application is for development of feed-forward control systems in industrial processes with fast transients.","abstract_has_math":false,"creators":["Baker, Karen Irene"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Dillaha, Theo A. III"],"committee_members":["Vick, Brian L.","Moses, Hal L."],"year":1993,"date_issued":"1993-05-19","date_published":"1993-05-19","updated_at":"2026-07-22T22:20:18Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12042009-020124"],"render_values":[{"text":"etd-12042009-020124","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/46091","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Dillaha, Theo A. III"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Vick, Brian L.","Moses, Hal L."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Baker, Karen Irene"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:50:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:50:55Z","2009-12-04"]},{"key":"dc:date.issued","label":"Date","values":["1993-05-19"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12042009-020124"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/46091"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A fast response thin-film heat flux sensor was used to measure the time-resolved surface heat flux and temperature from a turbulent combustion flame impinging on a surface. Using the analytical semi-infinite conduction model, the unsteady surface heat flux was calculated from the transient temperature measurements and the surface temperature was calculated from the unsteady surface heat flux measurements. Methods of comparing time-resolved heat flux and temperature data were presented and discussed. The standard analytical method for converting surface temperature to heat flux was used. Two new analytical methods were developed for converting heat flux to surface temperature. The study is the first demonstration of time-resolved temperature signals generated from time-resolved heat flux measurements. The results graphically illustrate the effects of data processing on electrical noise present in the actual signal. The effect of flame unsteadiness is also shown, especially in the time-resolved heat flux measurements, which gives insight into the behavior of a propane torch. One application is for development of feed-forward control systems in industrial processes with fast transients."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Unsteady surface heat flux and temperature measurements"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Dillaha, Theo A. III"],"dc:contributor.committeemember":["Vick, Brian L.","Moses, Hal L."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Baker, Karen Irene"],"dc:date.accessioned":["2014-03-14T21:50:55Z"],"dc:date.available":["2014-03-14T21:50:55Z","2009-12-04"],"dc:date.issued":["1993-05-19"],"dc:description.abstract":["A fast response thin-film heat flux sensor was used to measure the time-resolved surface heat flux and temperature from a turbulent combustion flame impinging on a surface. Using the analytical semi-infinite conduction model, the unsteady surface heat flux was calculated from the transient temperature measurements and the surface temperature was calculated from the unsteady surface heat flux measurements. Methods of comparing time-resolved heat flux and temperature data were presented and discussed. The standard analytical method for converting surface temperature to heat flux was used. Two new analytical methods were developed for converting heat flux to surface temperature. The study is the first demonstration of time-resolved temperature signals generated from time-resolved heat flux measurements. The results graphically illustrate the effects of data processing on electrical noise present in the actual signal. The effect of flame unsteadiness is also shown, especially in the time-resolved heat flux measurements, which gives insight into the behavior of a propane torch. One application is for development of feed-forward control systems in industrial processes with fast transients."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-12042009-020124"],"dc:identifier.uri":["http://hdl.handle.net/10919/46091"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Unsteady surface heat flux and temperature measurements"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:18Z"}