Back to results

Virginia Tech

Zero Quantum Nuclear Magnetic Resonance experiments utilizing a toroid cell and coil

Abstract

dc:description.abstract

Over the past ten to fifteen years the area of Nuclear Magnetic Resonance (NMR) Spectroscopy has seen tremendous growth. For example, in conjunction with multiple quantum NMR, molecular structural mapping of a compound can be easily performed in a two dimensional (2D) experiment. However, only two kinds of detector coils have been typically used in NMR studies. These are the solenoid coil and the Helmholtz coil. The solenoid coil was very popular with the permanent and electromagnet NMR instruments. With the advent of the superconducting magnets the popularity shifted to the Helmholtz coil, which remains the most common coil today for superconducting magnets. The Helmholtz coil, however, has been shown to have lower sensitivity than the solenoid coil. Hoult (1) has pointed out that potentially the Helmholtz coil represents a loss of signal-to-noise (S/N) by a factor of three in comparison to the solenoid coil. Since Hoult's original work, alternate methods for optimizing S/N have been explored. One of these has been the suggestion of toroid shaped resonators for NMR studies (2). A potential advantage of a toroid cell and coil is the confinement of the B₁ field to the torus region.It has been suggested that the toroid has a potential (S/N) advantage of 3.9 - 4.5 in comparison to the conventional Helmholtz cell (3). Since Zero Quantum (ZQ) experiments are independent of B₀ homogeneity, 2D ZQ experiments provide a convenient method of comparing the toroid and Helmholtz coils. In these zero quantum studies, the toroid and Helmholtz probes will be characterized in terms of several factors 1) B1 homogeneity, 2) B₀ homogeneity, 3) flip angle dependence, and 4) sensitivity. Finally, the two probes will be contrasted using spectral analysis in the spin-spin mapping of a simple molecule (nâ butanol) and a complex molecular system (taxol).

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Chemistry
Department dc:contributor.department
Chemistry
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1989

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bebout, William Roach
Chair dc:contributor.committeechair
  • Dorn, Harry C.
Committee members dc:contributor.committeemember
  • Schug, John C.
  • Taylor, Larry T.

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-11212012-040247
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/45968

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Bebout, William Roach. Zero Quantum Nuclear Magnetic Resonance experiments utilizing a toroid cell and coil. masters thesis, Virginia Tech, 1989. http://hdl.handle.net/10919/45968