Back to results

Virginia Tech

Investigation of column and instrumental parameters for fast gas chromatography analysis

Abstract

dc:description.abstract

The objective of this study was to determine the capability and applicability of a conventional gas chromatography system for fast chromatography. Many gas chromatographic separations actually require much Iss time than js actually being spent on the analysis. Capillary columns are known to be very efficient due to the long lengths and thin stationary phase films. However, analysis can be done much faster if shorter column lengths and thinner stationary phases are used because the retention time is a function of the column length and stationary phase film thickness. This study involves varying a number of column and instrumental parameters in order to determine their effect on the chromatographic analysis time. The parameters which were varied include the column stationary phase film thickness, the column length, the injection volume, the split ratio, the column position, the injector liner, and the flow and temperature programming rates. The effect of column length on the average linear gas velocity was also determined by plotting the Golay equation for each. The Golay equation (12) illustrates the effect of the various column parameters on column efficiency. The most detrimental effect of decreasing the analysis time is the loss of resolution that may occur. Both shorter lengths and faster than optimum flow rates result in lower resolution. By careful adjustment of some column parameters, the loss in resolution can be minimized. The results of this research show that many gas chromatographic analyses require much less time than is actually spent and that a fast analysis can be achieved with little to no loss in resolution.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Chemistry
Department dc:contributor.department
Chemistry
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1996

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Clark-Baker, Karen N.
Chair dc:contributor.committeechair
  • McNair, Harold M.
Committee members dc:contributor.committeemember
  • Long, Gary L.
  • Taylor, Larry T.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-11182008-063322
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/45853

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Clark-Baker, Karen N.. Investigation of column and instrumental parameters for fast gas chromatography analysis. masters thesis, Virginia Tech, 1996. http://hdl.handle.net/10919/45853