Back to results

Virginia Tech

Segmented footing system evaluation

Abstract

dc:description.abstract

Foundation construction for spread wall footings normally involves constructing formwork, placing reinforcement, and pouring and curing concrete, regardless of footing size or the amount of anticipated load. Recently, the National Concrete Masonry Association (NCMA) has developed a complete foundation system called the Footer Block system. It was designed to reduce the costs of foundation construction for 1 and 2 story buildings. The footer black system consists of interlocking concrete blocks 10.2 x 40.6 x 20.3 cm (4 x 16 x 8 in). Because they are placed with no mortar, delays associated with the curing process or providing access for concrete are unnecessary.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1987

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lewis, Tadeusz W.
Chair dc:contributor.committeechair
  • Krebs, R. D.
Committee members dc:contributor.committeemember
  • Clough, G. Wayne
  • Brandon, Thomas L.

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-11172012-040323
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/45815

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Lewis, Tadeusz W.. Segmented footing system evaluation. masters thesis, Virginia Tech, 1987. http://hdl.handle.net/10919/45815