{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45770"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45770","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The oscillogenic control algorithm","abstract":"An electronic-hardware-based oscillogenic controller previously developed by P. K. Mercure was used as a model for translation into a software-based control algoritnm. The oscillogenic instrument, invented by P. R. Rony and P. K. Mercure, uses a feedback element (the oscillogenic controller) and a sensor component to produces a periodic signal yielding information about the instrument's sensor component. A control program that utilized the oscillogenic control algorithm was written in the Turbo Pascal programming language. An IBM PC with 640 kilobytes of read/write memory and with analog-to-digital and digital-to-analog converter boards running the control program performed as the controller component of an oscillogenic instrument. A sample time of 0.5 seconds was used for this study. The instrument's sensor component consisted of a forced air thermal system with air flow rates ranging from 8.4 to 3l kg/hr. The oscillogenic instrument's frequency was, over the limited range tested (0.032 to 0.062 hz), a linear indication of the thermal system's convective heat transfer coefficient, which varied from 230 to 400 W/m²-°C.","abstract_html":"An electronic-hardware-based oscillogenic controller previously developed by P. K. Mercure was used as a model for translation into a software-based control algoritnm. The oscillogenic instrument, invented by P. R. Rony and P. K. Mercure, uses a feedback element (the oscillogenic controller) and a sensor component to produces a periodic signal yielding information about the instrument&#x27;s sensor component. A control program that utilized the oscillogenic control algorithm was written in the Turbo Pascal programming language. An IBM PC with 640 kilobytes of read/write memory and with analog-to-digital and digital-to-analog converter boards running the control program performed as the controller component of an oscillogenic instrument. A sample time of 0.5 seconds was used for this study. The instrument&#x27;s sensor component consisted of a forced air thermal system with air flow rates ranging from 8.4 to 3l kg/hr. The oscillogenic instrument&#x27;s frequency was, over the limited range tested (0.032 to 0.062 hz), a linear indication of the thermal system&#x27;s convective heat transfer coefficient, which varied from 230 to 400 W/m²-°C.","abstract_has_math":false,"creators":["McGraw, Philip E."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Chemical Engineering","degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Rony, Peter R."],"committee_members":["Konrad, Kenneth","McGee, M. A."],"year":1987,"date_issued":"1987-08-15","date_published":"1987-08-15","updated_at":"2026-07-22T22:19:03Z","subjects":[],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11172012-040021"],"render_values":[{"text":"etd-11172012-040021","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/45770","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Rony, Peter R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Konrad, Kenneth","McGee, M. A."]},{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:creator","label":"Author","values":["McGraw, Philip E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:49:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:49:52Z","2012-11-17"]},{"key":"dc:date.issued","label":"Date","values":["1987-08-15"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11172012-040021"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45770"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An electronic-hardware-based oscillogenic controller previously developed by P. K. Mercure was used as a model for translation into a software-based control algoritnm. The oscillogenic instrument, invented by P. R. Rony and P. K. Mercure, uses a feedback element (the oscillogenic controller) and a sensor component to produces a periodic signal yielding information about the instrument's sensor component. A control program that utilized the oscillogenic control algorithm was written in the Turbo Pascal programming language. An IBM PC with 640 kilobytes of read/write memory and with analog-to-digital and digital-to-analog converter boards running the control program performed as the controller component of an oscillogenic instrument. A sample time of 0.5 seconds was used for this study. The instrument's sensor component consisted of a forced air thermal system with air flow rates ranging from 8.4 to 3l kg/hr. The oscillogenic instrument's frequency was, over the limited range tested (0.032 to 0.062 hz), a linear indication of the thermal system's convective heat transfer coefficient, which varied from 230 to 400 W/m²-°C."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The oscillogenic control algorithm"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Rony, Peter R."],"dc:contributor.committeemember":["Konrad, Kenneth","McGee, M. A."],"dc:contributor.department":["Chemical Engineering"],"dc:creator":["McGraw, Philip E."],"dc:date.accessioned":["2014-03-14T21:49:52Z"],"dc:date.available":["2014-03-14T21:49:52Z","2012-11-17"],"dc:date.issued":["1987-08-15"],"dc:description.abstract":["An electronic-hardware-based oscillogenic controller previously developed by P. K. Mercure was used as a model for translation into a software-based control algoritnm. The oscillogenic instrument, invented by P. R. Rony and P. K. Mercure, uses a feedback element (the oscillogenic controller) and a sensor component to produces a periodic signal yielding information about the instrument's sensor component. A control program that utilized the oscillogenic control algorithm was written in the Turbo Pascal programming language. An IBM PC with 640 kilobytes of read/write memory and with analog-to-digital and digital-to-analog converter boards running the control program performed as the controller component of an oscillogenic instrument. A sample time of 0.5 seconds was used for this study. The instrument's sensor component consisted of a forced air thermal system with air flow rates ranging from 8.4 to 3l kg/hr. The oscillogenic instrument's frequency was, over the limited range tested (0.032 to 0.062 hz), a linear indication of the thermal system's convective heat transfer coefficient, which varied from 230 to 400 W/m²-°C."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-11172012-040021"],"dc:identifier.uri":["http://hdl.handle.net/10919/45770"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["The oscillogenic control algorithm"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:03Z"}