{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45744"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45744","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Uncooled choked plasma torch for ignition and flameholding in supersonic combustion","abstract":"An experimental investigation on an uncooled choked plasma torch using hydrogen/argon mixtures as a propellant was conducted. This low-power plasma torch was designed to be used as an ignitor and flameholder in supersonic combustion. The anode and cathode were made of two-percent thoriated tungsten, and no cooling system was required. Sonic flow through the nozzle was obtained by using a small throat diameter (0.813 mm). The plasma torch can operate stably over a wide range hydrogen/argon mixtures at power levels of 500 to 2000 W. Voltage-current characteristics of the arc are presented for discharge currents ranging from 5 to 40 A and for various flow rates and mixture fractions. The electrical input power is found to be a linear function of the hydrogen flow for a constant argon flow and for a current of 20 A. Measurements with a calorimeter reveal that the thermal efficiency, defined as the rate of increase of total enthalpy of the gas flowing through the torch divided by the electrical input power, is about 88 percent.","abstract_html":"An experimental investigation on an uncooled choked plasma torch using hydrogen/argon mixtures as a propellant was conducted. This low-power plasma torch was designed to be used as an ignitor and flameholder in supersonic combustion. The anode and cathode were made of two-percent thoriated tungsten, and no cooling system was required. Sonic flow through the nozzle was obtained by using a small throat diameter (0.813 mm). The plasma torch can operate stably over a wide range hydrogen/argon mixtures at power levels of 500 to 2000 W. Voltage-current characteristics of the arc are presented for discharge currents ranging from 5 to 40 A and for various flow rates and mixture fractions. The electrical input power is found to be a linear function of the hydrogen flow for a constant argon flow and for a current of 20 A. Measurements with a calorimeter reveal that the thermal efficiency, defined as the rate of increase of total enthalpy of the gas flowing through the torch divided by the electrical input power, is about 88 percent.","abstract_has_math":false,"creators":["Barbi, Eric"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["O'Brien, Walter F. Jr."],"committee_members":["Telionis, Demetri P.","Mahan, James Robert"],"year":1986,"date_issued":"1986-08-05","date_published":"1986-08-05","updated_at":"2026-07-22T22:19:15Z","subjects":[],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11152013-040422"],"render_values":[{"text":"etd-11152013-040422","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/45744","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["O'Brien, Walter F. Jr."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Telionis, Demetri P.","Mahan, James Robert"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Barbi, Eric"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:49:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:49:48Z","2013-11-15"]},{"key":"dc:date.issued","label":"Date","values":["1986-08-05"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11152013-040422"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45744"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental investigation on an uncooled choked plasma torch using hydrogen/argon mixtures as a propellant was conducted. This low-power plasma torch was designed to be used as an ignitor and flameholder in supersonic combustion. The anode and cathode were made of two-percent thoriated tungsten, and no cooling system was required. Sonic flow through the nozzle was obtained by using a small throat diameter (0.813 mm). The plasma torch can operate stably over a wide range hydrogen/argon mixtures at power levels of 500 to 2000 W. Voltage-current characteristics of the arc are presented for discharge currents ranging from 5 to 40 A and for various flow rates and mixture fractions. The electrical input power is found to be a linear function of the hydrogen flow for a constant argon flow and for a current of 20 A. Measurements with a calorimeter reveal that the thermal efficiency, defined as the rate of increase of total enthalpy of the gas flowing through the torch divided by the electrical input power, is about 88 percent."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Uncooled choked plasma torch for ignition and flameholding in supersonic combustion"]}]}],"canonical_facts":{"dc:contributor.committeechair":["O'Brien, Walter F. Jr."],"dc:contributor.committeemember":["Telionis, Demetri P.","Mahan, James Robert"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Barbi, Eric"],"dc:date.accessioned":["2014-03-14T21:49:48Z"],"dc:date.available":["2014-03-14T21:49:48Z","2013-11-15"],"dc:date.issued":["1986-08-05"],"dc:description.abstract":["An experimental investigation on an uncooled choked plasma torch using hydrogen/argon mixtures as a propellant was conducted. This low-power plasma torch was designed to be used as an ignitor and flameholder in supersonic combustion. The anode and cathode were made of two-percent thoriated tungsten, and no cooling system was required. Sonic flow through the nozzle was obtained by using a small throat diameter (0.813 mm). The plasma torch can operate stably over a wide range hydrogen/argon mixtures at power levels of 500 to 2000 W. Voltage-current characteristics of the arc are presented for discharge currents ranging from 5 to 40 A and for various flow rates and mixture fractions. The electrical input power is found to be a linear function of the hydrogen flow for a constant argon flow and for a current of 20 A. Measurements with a calorimeter reveal that the thermal efficiency, defined as the rate of increase of total enthalpy of the gas flowing through the torch divided by the electrical input power, is about 88 percent."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-11152013-040422"],"dc:identifier.uri":["http://hdl.handle.net/10919/45744"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Uncooled choked plasma torch for ignition and flameholding in supersonic combustion"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:15Z"}