{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45471"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45471","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Development and design of a test device for cartilage wear studies","abstract":"Articular cartilage is a material with the appearance of simplicity and uniformity, but the chemical and biological structure of this material is very complex and not yet known in every detail. Our knowledge of cartilage wear behavior is limited and needs to be enlarged. Knowledge in this area could be important for the prevention and treatment of degenerative joint diseases. Within the framework of this thesis. a literature search focused on the key words joint lubrication and cartilage wear was conducted. The result of this search was that almost all studies and experiments which have been carried out to investigate tribilogical processes in synovial joints focused on friction behavior. Only a few tests dealing with cartilage wear were conducted. Most of the cartilage wear studies were carried out under exaggerated conditions which might change the wear mechanisms. Two studies were undertaken under conditions close to normal conditions occurring in natural joints; one in entire joints with a pendulum device, the other one with a cartilage-on-cartilage test system. The test devices used in these tests offered no or limited opportunities for the variation of the test parameters. Test parameters are, for example, the type of motion, applied load, velocity, variation of the velocity during each cycle, type of specimen, and test fluid composition. In consideration of the findings of the literature search, it was decided to design a new test device providing the capability of measuring friction, wear, and displacement due to wear and/or cartilage deformation. Furthermore, the new test device for cartilage wear studies, allows the variation of the above mentioned test parameters.","abstract_html":"Articular cartilage is a material with the appearance of simplicity and uniformity, but the chemical and biological structure of this material is very complex and not yet known in every detail. Our knowledge of cartilage wear behavior is limited and needs to be enlarged. Knowledge in this area could be important for the prevention and treatment of degenerative joint diseases. Within the framework of this thesis. a literature search focused on the key words joint lubrication and cartilage wear was conducted. The result of this search was that almost all studies and experiments which have been carried out to investigate tribilogical processes in synovial joints focused on friction behavior. Only a few tests dealing with cartilage wear were conducted. Most of the cartilage wear studies were carried out under exaggerated conditions which might change the wear mechanisms. Two studies were undertaken under conditions close to normal conditions occurring in natural joints; one in entire joints with a pendulum device, the other one with a cartilage-on-cartilage test system. The test devices used in these tests offered no or limited opportunities for the variation of the test parameters. Test parameters are, for example, the type of motion, applied load, velocity, variation of the velocity during each cycle, type of specimen, and test fluid composition. In consideration of the findings of the literature search, it was decided to design a new test device providing the capability of measuring friction, wear, and displacement due to wear and/or cartilage deformation. Furthermore, the new test device for cartilage wear studies, allows the variation of the above mentioned test parameters.","abstract_has_math":false,"creators":["Burkhardt, Bettina M."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Furey, Michael J."],"committee_members":["Reinholtz, Charles F.","Kornegay, Ervin T."],"year":1988,"date_issued":"1988-12-04","date_published":"1988-12-04","updated_at":"2026-07-22T22:19:18Z","subjects":[],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11072008-063443"],"render_values":[{"text":"etd-11072008-063443","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/45471","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Furey, Michael J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Reinholtz, Charles F.","Kornegay, Ervin T."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Burkhardt, Bettina M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:49:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:49:04Z","2008-11-07"]},{"key":"dc:date.issued","label":"Date","values":["1988-12-04"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11072008-063443"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45471"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Articular cartilage is a material with the appearance of simplicity and uniformity, but the chemical and biological structure of this material is very complex and not yet known in every detail. Our knowledge of cartilage wear behavior is limited and needs to be enlarged. Knowledge in this area could be important for the prevention and treatment of degenerative joint diseases. Within the framework of this thesis. a literature search focused on the key words joint lubrication and cartilage wear was conducted. The result of this search was that almost all studies and experiments which have been carried out to investigate tribilogical processes in synovial joints focused on friction behavior. Only a few tests dealing with cartilage wear were conducted. Most of the cartilage wear studies were carried out under exaggerated conditions which might change the wear mechanisms. Two studies were undertaken under conditions close to normal conditions occurring in natural joints; one in entire joints with a pendulum device, the other one with a cartilage-on-cartilage test system. The test devices used in these tests offered no or limited opportunities for the variation of the test parameters. Test parameters are, for example, the type of motion, applied load, velocity, variation of the velocity during each cycle, type of specimen, and test fluid composition. In consideration of the findings of the literature search, it was decided to design a new test device providing the capability of measuring friction, wear, and displacement due to wear and/or cartilage deformation. Furthermore, the new test device for cartilage wear studies, allows the variation of the above mentioned test parameters."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development and design of a test device for cartilage wear studies"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Furey, Michael J."],"dc:contributor.committeemember":["Reinholtz, Charles F.","Kornegay, Ervin T."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Burkhardt, Bettina M."],"dc:date.accessioned":["2014-03-14T21:49:04Z"],"dc:date.available":["2014-03-14T21:49:04Z","2008-11-07"],"dc:date.issued":["1988-12-04"],"dc:description.abstract":["Articular cartilage is a material with the appearance of simplicity and uniformity, but the chemical and biological structure of this material is very complex and not yet known in every detail. Our knowledge of cartilage wear behavior is limited and needs to be enlarged. Knowledge in this area could be important for the prevention and treatment of degenerative joint diseases. Within the framework of this thesis. a literature search focused on the key words joint lubrication and cartilage wear was conducted. The result of this search was that almost all studies and experiments which have been carried out to investigate tribilogical processes in synovial joints focused on friction behavior. Only a few tests dealing with cartilage wear were conducted. Most of the cartilage wear studies were carried out under exaggerated conditions which might change the wear mechanisms. Two studies were undertaken under conditions close to normal conditions occurring in natural joints; one in entire joints with a pendulum device, the other one with a cartilage-on-cartilage test system. The test devices used in these tests offered no or limited opportunities for the variation of the test parameters. Test parameters are, for example, the type of motion, applied load, velocity, variation of the velocity during each cycle, type of specimen, and test fluid composition. In consideration of the findings of the literature search, it was decided to design a new test device providing the capability of measuring friction, wear, and displacement due to wear and/or cartilage deformation. Furthermore, the new test device for cartilage wear studies, allows the variation of the above mentioned test parameters."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-11072008-063443"],"dc:identifier.uri":["http://hdl.handle.net/10919/45471"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Development and design of a test device for cartilage wear studies"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:18Z"}