{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45356"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45356","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Optical method of recording electrical activity in isolated rabbit hearts","abstract":"A recently developed optical method utilizes a single, implantable, optical fiber to record electrical activity from isolated hearts stained with voltage-sensitive dyes. This optical technique generates recordings of transmembrane potential from excitable myocardial tissue, and remain free from stimulus artifacts that accompany electro stimulation and hinder all standard electrode recording methods during the application of high-voltage electrical shocks. The fiber optic system uses a l00J,lm diameter core fiber which can record from epicardial surface, internal mid-myocardium, or endocardial surfaces. The stained tissue is excited through the fiber and the resulting fluorescence is transmitted through the same fiber to a photomultiplier tube. Changes in fluorescence accompanying normal cardiac action potentials usually range from 1-5%. Substantive motion related signals accompany normal beating hearts, drowning out the actual signal that corresponds to change in membrane potential. When added to the nutrient solution of the heart, an excitation / contraction decoupler restricts motion and reduces the motion related signal making it easier to isolate the true membrane potential signal.","abstract_html":"A recently developed optical method utilizes a single, implantable, optical fiber to record electrical activity from isolated hearts stained with voltage-sensitive dyes. This optical technique generates recordings of transmembrane potential from excitable myocardial tissue, and remain free from stimulus artifacts that accompany electro stimulation and hinder all standard electrode recording methods during the application of high-voltage electrical shocks. The fiber optic system uses a l00J,lm diameter core fiber which can record from epicardial surface, internal mid-myocardium, or endocardial surfaces. The stained tissue is excited through the fiber and the resulting fluorescence is transmitted through the same fiber to a photomultiplier tube. Changes in fluorescence accompanying normal cardiac action potentials usually range from 1-5%. Substantive motion related signals accompany normal beating hearts, drowning out the actual signal that corresponds to change in membrane potential. When added to the nutrient solution of the heart, an excitation / contraction decoupler restricts motion and reduces the motion related signal making it easier to isolate the true membrane potential signal.","abstract_has_math":false,"creators":["Amanna, Ashwin E."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Krauthamer, Victor","Reed, Jeffrey H."],"committee_members":["Wang, Anbo"],"year":1993,"date_issued":"1993-12-01","date_published":"1993-12-01","updated_at":"2026-07-22T22:19:54Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10312009-020219"],"render_values":[{"text":"etd-10312009-020219","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/45356","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Krauthamer, Victor","Reed, Jeffrey H."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wang, Anbo"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Amanna, Ashwin E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:48:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:48:28Z","2009-10-31"]},{"key":"dc:date.issued","label":"Date","values":["1993-12-01"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10312009-020219"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45356"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A recently developed optical method utilizes a single, implantable, optical fiber to record electrical activity from isolated hearts stained with voltage-sensitive dyes. This optical technique generates recordings of transmembrane potential from excitable myocardial tissue, and remain free from stimulus artifacts that accompany electro stimulation and hinder all standard electrode recording methods during the application of high-voltage electrical shocks. The fiber optic system uses a l00J,lm diameter core fiber which can record from epicardial surface, internal mid-myocardium, or endocardial surfaces. The stained tissue is excited through the fiber and the resulting fluorescence is transmitted through the same fiber to a photomultiplier tube. Changes in fluorescence accompanying normal cardiac action potentials usually range from 1-5%. Substantive motion related signals accompany normal beating hearts, drowning out the actual signal that corresponds to change in membrane potential. When added to the nutrient solution of the heart, an excitation / contraction decoupler restricts motion and reduces the motion related signal making it easier to isolate the true membrane potential signal."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Optical method of recording electrical activity in isolated rabbit hearts"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Krauthamer, Victor","Reed, Jeffrey H."],"dc:contributor.committeemember":["Wang, Anbo"],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Amanna, Ashwin E."],"dc:date.accessioned":["2014-03-14T21:48:28Z"],"dc:date.available":["2014-03-14T21:48:28Z","2009-10-31"],"dc:date.issued":["1993-12-01"],"dc:description.abstract":["A recently developed optical method utilizes a single, implantable, optical fiber to record electrical activity from isolated hearts stained with voltage-sensitive dyes. This optical technique generates recordings of transmembrane potential from excitable myocardial tissue, and remain free from stimulus artifacts that accompany electro stimulation and hinder all standard electrode recording methods during the application of high-voltage electrical shocks. The fiber optic system uses a l00J,lm diameter core fiber which can record from epicardial surface, internal mid-myocardium, or endocardial surfaces. The stained tissue is excited through the fiber and the resulting fluorescence is transmitted through the same fiber to a photomultiplier tube. Changes in fluorescence accompanying normal cardiac action potentials usually range from 1-5%. Substantive motion related signals accompany normal beating hearts, drowning out the actual signal that corresponds to change in membrane potential. When added to the nutrient solution of the heart, an excitation / contraction decoupler restricts motion and reduces the motion related signal making it easier to isolate the true membrane potential signal."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-10312009-020219"],"dc:identifier.uri":["http://hdl.handle.net/10919/45356"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Optical method of recording electrical activity in isolated rabbit hearts"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:54Z"}