Back to results

Virginia Tech

An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs

Abstract

dc:description.abstract

Expanding the standard, single-well recording geometry used to monitor seismicity during hydro-fracture treatments could provide more accurate hypocenter locations and seismic velocities, improving general reservoir characterization. However, for the real, two-well data set obtained for this project, only S-wave picks were available, and testing resulted in anomalous hypocenter location behavior. This study uses a hypocenter location algorithm and both real and synthetic data sets to investigate how the accuracy of the velocity model, starting hypocenter location, recording geometry, and arrival-time picking error affect final hypocenter locations. Hypocenter locations improved using a velocity model that closely matched the observed sonic log rather than a smoothed version of this model. The starting hypocenter location did not affect the final location solution if both starting and final locations were between the wells. Two solutions were possible when the true solution was not directly between the wells. Adding realistic random picking errors to synthetic data closely modeled the dispersed hypocenter error pattern observed in the real data results. Adding data from a third well to synthetic tests dramatically reduced location error and removed horizontal geometric bias observed in the two-well case. Seismic event data recorded during hydro-fracture treatments could potentially be used for three-dimensional joint hypocenter-velocity tomography. This would require observation wells close enough to earthquakes to record P- and S-wave arrivals or wells at orientations sufficient to properly triangulate hypocenter locations. Simulating results with synthetic tests before drilling could optimize survey design to collect data more effectively and make analysis more useful.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Geosciences
Department dc:contributor.department
Geosciences
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gilliland, Ellen
Chair dc:contributor.committeechair
  • Hole, John A.
Committee members dc:contributor.committeemember
  • Weiss, Chester J.
  • Chapman, Martin C.

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-10272009-165453
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/45325

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Gilliland, Ellen. An Assessment of Hypocenter Errors Associated with the Seismic Monitoring of Induced Hydro-fracturing in Hydrocarbon Reservoirs. masters thesis, Virginia Tech, 2009. http://hdl.handle.net/10919/45325