{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45263"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45263","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The development of instrumentation for the support of skin friction and heat flux measurements","abstract":"Instrumentation has been designed to process the signals from two types of skin friction gages and a microfabricated heat flux gage. Design changes for the skin friction gages are presented which will improve the performance of the two transducers. The instrumentation is simple in design and use and has been designed to maximize the performance of the skin friction and heat flux gages. The instrumentation is battery powered to minimize noise levels and to maintain instrumentation portability. A high-quality instrumentation amplifier, a voltage regulator, and a custom-designed circuit board have been combined to produce an instrumentation package which is stable and durable. The instrumentation has been specifically designed to handle low-level signals and can operate over a wide range of frequencies. Problems commonly associated with low-level signal conditioning like electrical noise, nonlinearities, and output drift are addressed. The performance specifications of the instrumentation are presented along with sample gage measurements.","abstract_html":"Instrumentation has been designed to process the signals from two types of skin friction gages and a microfabricated heat flux gage. Design changes for the skin friction gages are presented which will improve the performance of the two transducers. The instrumentation is simple in design and use and has been designed to maximize the performance of the skin friction and heat flux gages. The instrumentation is battery powered to minimize noise levels and to maintain instrumentation portability. A high-quality instrumentation amplifier, a voltage regulator, and a custom-designed circuit board have been combined to produce an instrumentation package which is stable and durable. The instrumentation has been specifically designed to handle low-level signals and can operate over a wide range of frequencies. Problems commonly associated with low-level signal conditioning like electrical noise, nonlinearities, and output drift are addressed. The performance specifications of the instrumentation are presented along with sample gage measurements.","abstract_has_math":false,"creators":["Putz, John M."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991","date_published":"1991","updated_at":"2026-07-24T05:56:14Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10222009-125136"],"render_values":[{"text":"etd-10222009-125136","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/45263","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Putz, John M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:48:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:48:02Z","2009-10-22"]},{"key":"dc:date.issued","label":"Date","values":["1991"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10222009-125136"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45263"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Instrumentation has been designed to process the signals from two types of skin friction gages and a microfabricated heat flux gage. Design changes for the skin friction gages are presented which will improve the performance of the two transducers. The instrumentation is simple in design and use and has been designed to maximize the performance of the skin friction and heat flux gages. The instrumentation is battery powered to minimize noise levels and to maintain instrumentation portability. A high-quality instrumentation amplifier, a voltage regulator, and a custom-designed circuit board have been combined to produce an instrumentation package which is stable and durable. The instrumentation has been specifically designed to handle low-level signals and can operate over a wide range of frequencies. Problems commonly associated with low-level signal conditioning like electrical noise, nonlinearities, and output drift are addressed. The performance specifications of the instrumentation are presented along with sample gage measurements."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The development of instrumentation for the support of skin friction and heat flux measurements"]}]}],"canonical_facts":{"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Putz, John M."],"dc:date.accessioned":["2014-03-14T21:48:02Z"],"dc:date.available":["2014-03-14T21:48:02Z","2009-10-22"],"dc:date.issued":["1991"],"dc:description.abstract":["Instrumentation has been designed to process the signals from two types of skin friction gages and a microfabricated heat flux gage. Design changes for the skin friction gages are presented which will improve the performance of the two transducers. The instrumentation is simple in design and use and has been designed to maximize the performance of the skin friction and heat flux gages. The instrumentation is battery powered to minimize noise levels and to maintain instrumentation portability. A high-quality instrumentation amplifier, a voltage regulator, and a custom-designed circuit board have been combined to produce an instrumentation package which is stable and durable. The instrumentation has been specifically designed to handle low-level signals and can operate over a wide range of frequencies. Problems commonly associated with low-level signal conditioning like electrical noise, nonlinearities, and output drift are addressed. The performance specifications of the instrumentation are presented along with sample gage measurements."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-10222009-125136"],"dc:identifier.uri":["http://hdl.handle.net/10919/45263"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["The development of instrumentation for the support of skin friction and heat flux measurements"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-24T05:56:14Z"}