{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/44824"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/44824","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The use of tuned mass dampers to control annoying floor vibrations","abstract":"Floor vibrations due to occupancy activities on a floor are sometimes annoying to the occupants. Correcting floor vibrations is difficult and can be expensive. The use of tuned mass dampers to control annoying floor vibrations is sometimes a viable solution. Tuned mass dampers (TMDs) have been used primarily to control only one or two modes of vibration of a floor. Experimental research was performed using prototype TMDs to control one, two, and three modes of vibration of various floors. Results from this research are presented in this thesis. Analytical research, performed to obtain information about floor vibration characteristics, is presented and used for the initial design of TMDs and placement of TMDs on a floor. Also, computer models of the floors with TMDs to control one, two, and three modes of vibration were analyzed to obtain further information about changes in floor response and vibration characteristics. This research was performed to provide further insight on the effectiveness of TMDs to control one, two, and three modes of floor vibration and the effects of TMDs on floor vibration characteristics.","abstract_html":"Floor vibrations due to occupancy activities on a floor are sometimes annoying to the occupants. Correcting floor vibrations is difficult and can be expensive. The use of tuned mass dampers to control annoying floor vibrations is sometimes a viable solution. Tuned mass dampers (TMDs) have been used primarily to control only one or two modes of vibration of a floor. Experimental research was performed using prototype TMDs to control one, two, and three modes of vibration of various floors. Results from this research are presented in this thesis. Analytical research, performed to obtain information about floor vibration characteristics, is presented and used for the initial design of TMDs and placement of TMDs on a floor. Also, computer models of the floors with TMDs to control one, two, and three modes of vibration were analyzed to obtain further information about changes in floor response and vibration characteristics. This research was performed to provide further insight on the effectiveness of TMDs to control one, two, and three modes of floor vibration and the effects of TMDs on floor vibration characteristics.","abstract_has_math":false,"creators":["Rottmann, Cheryl E."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1996,"date_issued":"1996","date_published":"1996","updated_at":"2026-07-22T22:18:58Z","subjects":["tuned mass damper","floor vibration"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-09182008-063455"],"render_values":[{"text":"etd-09182008-063455","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/44824","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Rottmann, Cheryl E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:46:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:46:02Z","2008-09-18"]},{"key":"dc:date.issued","label":"Date","values":["1996"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["tuned mass damper","floor vibration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-09182008-063455"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/44824"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Floor vibrations due to occupancy activities on a floor are sometimes annoying to the occupants. Correcting floor vibrations is difficult and can be expensive. The use of tuned mass dampers to control annoying floor vibrations is sometimes a viable solution. Tuned mass dampers (TMDs) have been used primarily to control only one or two modes of vibration of a floor. Experimental research was performed using prototype TMDs to control one, two, and three modes of vibration of various floors. Results from this research are presented in this thesis. Analytical research, performed to obtain information about floor vibration characteristics, is presented and used for the initial design of TMDs and placement of TMDs on a floor. Also, computer models of the floors with TMDs to control one, two, and three modes of vibration were analyzed to obtain further information about changes in floor response and vibration characteristics. This research was performed to provide further insight on the effectiveness of TMDs to control one, two, and three modes of floor vibration and the effects of TMDs on floor vibration characteristics."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The use of tuned mass dampers to control annoying floor vibrations"]}]}],"canonical_facts":{"dc:contributor.department":["Civil Engineering"],"dc:creator":["Rottmann, Cheryl E."],"dc:date.accessioned":["2014-03-14T21:46:02Z"],"dc:date.available":["2014-03-14T21:46:02Z","2008-09-18"],"dc:date.issued":["1996"],"dc:description.abstract":["Floor vibrations due to occupancy activities on a floor are sometimes annoying to the occupants. Correcting floor vibrations is difficult and can be expensive. The use of tuned mass dampers to control annoying floor vibrations is sometimes a viable solution. Tuned mass dampers (TMDs) have been used primarily to control only one or two modes of vibration of a floor. Experimental research was performed using prototype TMDs to control one, two, and three modes of vibration of various floors. Results from this research are presented in this thesis. Analytical research, performed to obtain information about floor vibration characteristics, is presented and used for the initial design of TMDs and placement of TMDs on a floor. Also, computer models of the floors with TMDs to control one, two, and three modes of vibration were analyzed to obtain further information about changes in floor response and vibration characteristics. This research was performed to provide further insight on the effectiveness of TMDs to control one, two, and three modes of floor vibration and the effects of TMDs on floor vibration characteristics."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-09182008-063455"],"dc:identifier.uri":["http://hdl.handle.net/10919/44824"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["tuned mass damper","floor vibration"],"dc:title":["The use of tuned mass dampers to control annoying floor vibrations"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:18:58Z"}