Back to results

Virginia Tech

Physiological and perceptual assessment of thermal comfort and heat strain in garment wear tests using sleeves: an alternative to full-garment tests of chemical protective clothing

Abstract

dc:description.abstract

This study was conducted to explore the feasibility of using sleeves, along with both physiological and perceptual measurements, to assess the thermal comfort and heat strain in chemical protective clothing wear tests. The effect of body sites, i.e. the arms and the chest, and the effect of a Tyvek® coverall on skin temperature and sweat amount were investigated as well. Ten male subjects were selected from college students. Each subject was assigned to wear a garment of either T-shirt and pants or a changeable left-sleeved Tyvek® coverall with or without an experimental sleeve on the left arm. Three experimental sleeves were of the same style, but made of three different fabrics: Tyvek®, Pro/Shield I®, and Pro/Shield II®. Each subject wore an assigned garment and pedaled on a cycle ergometer in an environmentally-controlled room. Skin temperature, sweat amount, and subjective comfort evaluations were recorded and later analyzed by repeated-measures ANOVA. Results showed there is a feasibility in using a sleeve with a T-shirt/pants standard garment for assessing thermal comfort in chemical protective garment wear tests. The T-shirt/pants standard garment yielded more consistent and reliable results than did the Tyvek®-coverall standard garment. Under the same conditions, there were no significant differences in skin temperature and sweat amount among the left and right upper arms and the chest. The Tyvek® sleeve in this study impeded the transfer of heat by the greatest amount, followed by the Pro/Shield II® sleeve and the Pro/Shield I® sleeve, respectively.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Clothing and Textiles
Department dc:contributor.department
Clothing and Textiles
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1996

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tultrairat, Angkhana
Chairs dc:contributor.committeechair
  • Norton, Marjorie
  • Cloud, Rinn M.
Committee members dc:contributor.committeemember
  • Boles, Joann F.
  • Herbert, William G.

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-08292008-063420
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/44494

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Tultrairat, Angkhana. Physiological and perceptual assessment of thermal comfort and heat strain in garment wear tests using sleeves: an alternative to full-garment tests of chemical protective clothing. masters thesis, Virginia Tech, 1996. http://hdl.handle.net/10919/44494