{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/44350"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/44350","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Effects of stationary wake on turbine blade heat transfer in a transonic cascade","abstract":"The effects of a wake generated by a stationary upstream strut on surface heat transfer to turbine blades were measured experimentally. Time-resolved and unsteady heat flux measurements were made with Heat Flux Microsensors (HFM) at three positions on the suction surface and one position on the pressure surface of a turbine blade. The experiments were conducted on a stationary cascade of blades for heated runs at transonic conditions Methods for determining the adiabatic wall temperature and heat transfer coefficient are presented and the results are compared to computer predictions for these blades. Heat transfer measurements were taken with new HFM-6 insert gages. A strong influence on the heat transfer coefficient was seen from the relative position of the strut with respect to the leading edge of the test blades. As the strut approached the leading edge of the blade the heat transfer increased by 15% at gage location 2 on the suction surface. The largest increase in .the heat transfer coefficient was seen on the pressure surface. Results at this location show a 24% increase in the overall heat transfer coefficient for one of the strut locations. The values obtained for the heat transfer coefficients for the no strut case did not compare well with computer predictions. The results did support the experimental results of other researchers, however. The fast time response of the HFM illustrated graphically an increase in the frequency energy between the 0-10 kHz range when the strut was located near the leading edge of the instrumented blade. The heat flux turbulence intensity (Tuq) was defined as another physical quantity important to turbine blade heat transfer, but no conclusions could be drawn from the results as to how this value compares to the turbulence intensity.","abstract_html":"The effects of a wake generated by a stationary upstream strut on surface heat transfer to turbine blades were measured experimentally. Time-resolved and unsteady heat flux measurements were made with Heat Flux Microsensors (HFM) at three positions on the suction surface and one position on the pressure surface of a turbine blade. The experiments were conducted on a stationary cascade of blades for heated runs at transonic conditions Methods for determining the adiabatic wall temperature and heat transfer coefficient are presented and the results are compared to computer predictions for these blades. Heat transfer measurements were taken with new HFM-6 insert gages. A strong influence on the heat transfer coefficient was seen from the relative position of the strut with respect to the leading edge of the test blades. As the strut approached the leading edge of the blade the heat transfer increased by 15% at gage location 2 on the suction surface. The largest increase in .the heat transfer coefficient was seen on the pressure surface. Results at this location show a 24% increase in the overall heat transfer coefficient for one of the strut locations. The values obtained for the heat transfer coefficients for the no strut case did not compare well with computer predictions. The results did support the experimental results of other researchers, however. The fast time response of the HFM illustrated graphically an increase in the frequency energy between the 0-10 kHz range when the strut was located near the leading edge of the instrumented blade. The heat flux turbulence intensity (Tuq) was defined as another physical quantity important to turbine blade heat transfer, but no conclusions could be drawn from the results as to how this value compares to the turbulence intensity.","abstract_has_math":false,"creators":["Hale, Jamie Harold"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Diller, Thomas E.","Ng, Fai"],"committee_members":["Schetz, Joseph A."],"year":1996,"date_issued":"1996-04-15","date_published":"1996-04-15","updated_at":"2026-07-22T22:19:16Z","subjects":["transonic cascade","turbine blade heat transfer","stationary wake"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08222008-063626"],"render_values":[{"text":"etd-08222008-063626","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/44350","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Diller, Thomas E.","Ng, Fai"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Schetz, Joseph A."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Hale, Jamie Harold"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:43:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:43:15Z","2008-08-22"]},{"key":"dc:date.issued","label":"Date","values":["1996-04-15"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["transonic cascade","turbine blade heat transfer","stationary wake"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08222008-063626"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/44350"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The effects of a wake generated by a stationary upstream strut on surface heat transfer to turbine blades were measured experimentally. Time-resolved and unsteady heat flux measurements were made with Heat Flux Microsensors (HFM) at three positions on the suction surface and one position on the pressure surface of a turbine blade. The experiments were conducted on a stationary cascade of blades for heated runs at transonic conditions Methods for determining the adiabatic wall temperature and heat transfer coefficient are presented and the results are compared to computer predictions for these blades. Heat transfer measurements were taken with new HFM-6 insert gages. A strong influence on the heat transfer coefficient was seen from the relative position of the strut with respect to the leading edge of the test blades. As the strut approached the leading edge of the blade the heat transfer increased by 15% at gage location 2 on the suction surface. The largest increase in .the heat transfer coefficient was seen on the pressure surface. Results at this location show a 24% increase in the overall heat transfer coefficient for one of the strut locations. The values obtained for the heat transfer coefficients for the no strut case did not compare well with computer predictions. The results did support the experimental results of other researchers, however. The fast time response of the HFM illustrated graphically an increase in the frequency energy between the 0-10 kHz range when the strut was located near the leading edge of the instrumented blade. The heat flux turbulence intensity (Tuq) was defined as another physical quantity important to turbine blade heat transfer, but no conclusions could be drawn from the results as to how this value compares to the turbulence intensity."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Effects of stationary wake on turbine blade heat transfer in a transonic cascade"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Diller, Thomas E.","Ng, Fai"],"dc:contributor.committeemember":["Schetz, Joseph A."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Hale, Jamie Harold"],"dc:date.accessioned":["2014-03-14T21:43:15Z"],"dc:date.available":["2014-03-14T21:43:15Z","2008-08-22"],"dc:date.issued":["1996-04-15"],"dc:description.abstract":["The effects of a wake generated by a stationary upstream strut on surface heat transfer to turbine blades were measured experimentally. Time-resolved and unsteady heat flux measurements were made with Heat Flux Microsensors (HFM) at three positions on the suction surface and one position on the pressure surface of a turbine blade. The experiments were conducted on a stationary cascade of blades for heated runs at transonic conditions Methods for determining the adiabatic wall temperature and heat transfer coefficient are presented and the results are compared to computer predictions for these blades. Heat transfer measurements were taken with new HFM-6 insert gages. A strong influence on the heat transfer coefficient was seen from the relative position of the strut with respect to the leading edge of the test blades. As the strut approached the leading edge of the blade the heat transfer increased by 15% at gage location 2 on the suction surface. The largest increase in .the heat transfer coefficient was seen on the pressure surface. Results at this location show a 24% increase in the overall heat transfer coefficient for one of the strut locations. The values obtained for the heat transfer coefficients for the no strut case did not compare well with computer predictions. The results did support the experimental results of other researchers, however. The fast time response of the HFM illustrated graphically an increase in the frequency energy between the 0-10 kHz range when the strut was located near the leading edge of the instrumented blade. The heat flux turbulence intensity (Tuq) was defined as another physical quantity important to turbine blade heat transfer, but no conclusions could be drawn from the results as to how this value compares to the turbulence intensity."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-08222008-063626"],"dc:identifier.uri":["http://hdl.handle.net/10919/44350"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["transonic cascade","turbine blade heat transfer","stationary wake"],"dc:title":["Effects of stationary wake on turbine blade heat transfer in a transonic cascade"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:16Z"}