{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/44083"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/44083","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The use of hot-wire anemometry in studying supersonic slot injection into a supersonic flow","abstract":"Tangential supersonic slot injection (M = 1.7) of air into a supersonic air stream (M = 2.91) was studied with a dual hot wire probe. This probe was used to simultaneously determine total temperature and mass flux. Mean profiles across the entire flow field at three axial stations (x/h = 4, 10, 20) were obtained, as well as the temperature and mass flux turbulence intensities. The probe can be used anywhere except at locations where features of the flow are smaller than the separation between the wires (0.18 mm). The calibration of the probe can be repeated with less than a three percent change in calculated Nusselt number. The hot wire probe can also be tuned to obtain a high frequency response. The interaction of a shock wave, caused by a wedge placed on the upper tunnel wall, with the mixing region was investigated. Little change in the mean profiles was observed, but there was a significant increase in turbulence levels.","abstract_html":"Tangential supersonic slot injection (M = 1.7) of air into a supersonic air stream (M = 2.91) was studied with a dual hot wire probe. This probe was used to simultaneously determine total temperature and mass flux. Mean profiles across the entire flow field at three axial stations (x/h = 4, 10, 20) were obtained, as well as the temperature and mass flux turbulence intensities. The probe can be used anywhere except at locations where features of the flow are smaller than the separation between the wires (0.18 mm). The calibration of the probe can be repeated with less than a three percent change in calculated Nusselt number. The hot wire probe can also be tuned to obtain a high frequency response. The interaction of a shock wave, caused by a wedge placed on the upper tunnel wall, with the mixing region was investigated. Little change in the mean profiles was observed, but there was a significant increase in turbulence levels.","abstract_has_math":false,"creators":["Rettew, A. Louisa"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Ng, Wing Fai"],"committee_members":["Senetz, Joseph A.","Dancey, Clinton L."],"year":1988,"date_issued":"1988-02-05","date_published":"1988-02-05","updated_at":"2026-07-22T22:19:53Z","subjects":[],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08012012-040342"],"render_values":[{"text":"etd-08012012-040342","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/44083","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Ng, Wing Fai"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Senetz, Joseph A.","Dancey, Clinton L."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Rettew, A. Louisa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:41:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:41:58Z","2012-08-01"]},{"key":"dc:date.issued","label":"Date","values":["1988-02-05"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08012012-040342"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/44083"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Tangential supersonic slot injection (M = 1.7) of air into a supersonic air stream (M = 2.91) was studied with a dual hot wire probe. This probe was used to simultaneously determine total temperature and mass flux. Mean profiles across the entire flow field at three axial stations (x/h = 4, 10, 20) were obtained, as well as the temperature and mass flux turbulence intensities. The probe can be used anywhere except at locations where features of the flow are smaller than the separation between the wires (0.18 mm). The calibration of the probe can be repeated with less than a three percent change in calculated Nusselt number. The hot wire probe can also be tuned to obtain a high frequency response. The interaction of a shock wave, caused by a wedge placed on the upper tunnel wall, with the mixing region was investigated. Little change in the mean profiles was observed, but there was a significant increase in turbulence levels."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The use of hot-wire anemometry in studying supersonic slot injection into a supersonic flow"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Ng, Wing Fai"],"dc:contributor.committeemember":["Senetz, Joseph A.","Dancey, Clinton L."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Rettew, A. Louisa"],"dc:date.accessioned":["2014-03-14T21:41:58Z"],"dc:date.available":["2014-03-14T21:41:58Z","2012-08-01"],"dc:date.issued":["1988-02-05"],"dc:description.abstract":["Tangential supersonic slot injection (M = 1.7) of air into a supersonic air stream (M = 2.91) was studied with a dual hot wire probe. This probe was used to simultaneously determine total temperature and mass flux. Mean profiles across the entire flow field at three axial stations (x/h = 4, 10, 20) were obtained, as well as the temperature and mass flux turbulence intensities. The probe can be used anywhere except at locations where features of the flow are smaller than the separation between the wires (0.18 mm). The calibration of the probe can be repeated with less than a three percent change in calculated Nusselt number. The hot wire probe can also be tuned to obtain a high frequency response. The interaction of a shock wave, caused by a wedge placed on the upper tunnel wall, with the mixing region was investigated. Little change in the mean profiles was observed, but there was a significant increase in turbulence levels."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-08012012-040342"],"dc:identifier.uri":["http://hdl.handle.net/10919/44083"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["The use of hot-wire anemometry in studying supersonic slot injection into a supersonic flow"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:53Z"}