{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/43847"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/43847","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Floc density measurement and the effects of microproperty variations on sludge dewatering characteristics","abstract":"The dewatering characteristics of sludges produced by water and wastewater treatment plants bear heavily on the methods chosen to treat and dispose of the sludge, as well as on the costs associated with handling the large volumes of sludge produced at these facilities. This study investigated why different sludges dewater to different dry solids concentrations, how sludge structure affects dewatering, and how sludge structure changes during gravity thickening and during different types of mechanical dewatering. It is generally thought that sludge can be described as having a three-tiered structure: (1) primary particles, (2) floc particles, and (3) aggregate particles. To investigate sludge structure in relation to sludge dewatering, this study has defined sludge structure using several sludge particle micro properties. A laboratory technique incorporating isopycnic centrifugation in gradients of Percoll<sup>R</sup> media was developed to measure one micro property known as floc particle density. Six field and laboratory sludges were subjected to a series of dewatering tests: gravity thickening, centrifugation, and vacuum filtration. Each sludge was analyzed for macro- and micro properties through each stage of dewatering. It was concluded that improvements in thickening and dewatering characteristics were heavily dependent upon increases in sludge floc density and decreases in aggregate water content.","abstract_html":"The dewatering characteristics of sludges produced by water and wastewater treatment plants bear heavily on the methods chosen to treat and dispose of the sludge, as well as on the costs associated with handling the large volumes of sludge produced at these facilities. This study investigated why different sludges dewater to different dry solids concentrations, how sludge structure affects dewatering, and how sludge structure changes during gravity thickening and during different types of mechanical dewatering. It is generally thought that sludge can be described as having a three-tiered structure: (1) primary particles, (2) floc particles, and (3) aggregate particles. To investigate sludge structure in relation to sludge dewatering, this study has defined sludge structure using several sludge particle micro properties. A laboratory technique incorporating isopycnic centrifugation in gradients of Percoll&lt;sup&gt;R&lt;/sup&gt; media was developed to measure one micro property known as floc particle density. Six field and laboratory sludges were subjected to a series of dewatering tests: gravity thickening, centrifugation, and vacuum filtration. Each sludge was analyzed for macro- and micro properties through each stage of dewatering. It was concluded that improvements in thickening and dewatering characteristics were heavily dependent upon increases in sludge floc density and decreases in aggregate water content.","abstract_has_math":false,"creators":["Dishman, C. Michael"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Environmental Planning","degree_department":"Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Knocke, William R."],"committee_members":["Novak, John T.","Sherrard, Joseph H."],"year":1988,"date_issued":"1988-12-05","date_published":"1988-12-05","updated_at":"2026-07-22T22:19:49Z","subjects":[],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07212010-020337"],"render_values":[{"text":"etd-07212010-020337","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/43847","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Knocke, William R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Novak, John T.","Sherrard, Joseph H."]},{"key":"dc:contributor.department","label":"Department","values":["Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Dishman, C. Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:40:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:40:59Z","2010-07-21"]},{"key":"dc:date.issued","label":"Date","values":["1988-12-05"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental Planning"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07212010-020337"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/43847"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The dewatering characteristics of sludges produced by water and wastewater treatment plants bear heavily on the methods chosen to treat and dispose of the sludge, as well as on the costs associated with handling the large volumes of sludge produced at these facilities. This study investigated why different sludges dewater to different dry solids concentrations, how sludge structure affects dewatering, and how sludge structure changes during gravity thickening and during different types of mechanical dewatering. It is generally thought that sludge can be described as having a three-tiered structure: (1) primary particles, (2) floc particles, and (3) aggregate particles. To investigate sludge structure in relation to sludge dewatering, this study has defined sludge structure using several sludge particle micro properties. A laboratory technique incorporating isopycnic centrifugation in gradients of Percoll<sup>R</sup> media was developed to measure one micro property known as floc particle density. Six field and laboratory sludges were subjected to a series of dewatering tests: gravity thickening, centrifugation, and vacuum filtration. Each sludge was analyzed for macro- and micro properties through each stage of dewatering. It was concluded that improvements in thickening and dewatering characteristics were heavily dependent upon increases in sludge floc density and decreases in aggregate water content."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Floc density measurement and the effects of microproperty variations on sludge dewatering characteristics"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Knocke, William R."],"dc:contributor.committeemember":["Novak, John T.","Sherrard, Joseph H."],"dc:contributor.department":["Environmental Engineering"],"dc:creator":["Dishman, C. Michael"],"dc:date.accessioned":["2014-03-14T21:40:59Z"],"dc:date.available":["2014-03-14T21:40:59Z","2010-07-21"],"dc:date.issued":["1988-12-05"],"dc:description.abstract":["The dewatering characteristics of sludges produced by water and wastewater treatment plants bear heavily on the methods chosen to treat and dispose of the sludge, as well as on the costs associated with handling the large volumes of sludge produced at these facilities. This study investigated why different sludges dewater to different dry solids concentrations, how sludge structure affects dewatering, and how sludge structure changes during gravity thickening and during different types of mechanical dewatering. It is generally thought that sludge can be described as having a three-tiered structure: (1) primary particles, (2) floc particles, and (3) aggregate particles. To investigate sludge structure in relation to sludge dewatering, this study has defined sludge structure using several sludge particle micro properties. A laboratory technique incorporating isopycnic centrifugation in gradients of Percoll<sup>R</sup> media was developed to measure one micro property known as floc particle density. Six field and laboratory sludges were subjected to a series of dewatering tests: gravity thickening, centrifugation, and vacuum filtration. Each sludge was analyzed for macro- and micro properties through each stage of dewatering. It was concluded that improvements in thickening and dewatering characteristics were heavily dependent upon increases in sludge floc density and decreases in aggregate water content."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-07212010-020337"],"dc:identifier.uri":["http://hdl.handle.net/10919/43847"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Floc density measurement and the effects of microproperty variations on sludge dewatering characteristics"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Environmental Planning"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:49Z"}