{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/43686"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/43686","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"An experimental investigation of turbine blade tip heat transfer and tip gap flows in the supersonic regime","abstract":"Gas turbine blade tip heat transfer and tip gap flow phenomena has been explored experimentally in a stationary cascade for blade exit Mach numbers = 1.2 to 1.4. Experimental results were found to agree well with qualitative predictions performed at GE Aircraft Engines. The pressure distribution in the blade tip cavity of a grooved tip blade was found to vary little with either Mach number or tip gap height. The tip cavity pressure was, however, a strong function of location. The tip cavity pressure distribution coupled with the pressure side distribution near the tip was speculated to drive the leakage flow across the blade tip from mid-chord aft based on surface flow visualization studies using an oil/dye mixture. Heat flux on the tip cavity floor was successfully measured using a thin-film Heat Flux Microsensor. Results of these measurements are consistent with previous studies in the subsonic regime. The convection coefficients on the tip cavity floor were found to be three times those found on the suction side airfoil surface near the trailing edge. Convection coefficients were found not to vary with either tip gap height or Mach number. The fluctuating component of heat flux was found to be at least 25% of the total heat flux.","abstract_html":"Gas turbine blade tip heat transfer and tip gap flow phenomena has been explored experimentally in a stationary cascade for blade exit Mach numbers = 1.2 to 1.4. Experimental results were found to agree well with qualitative predictions performed at GE Aircraft Engines. The pressure distribution in the blade tip cavity of a grooved tip blade was found to vary little with either Mach number or tip gap height. The tip cavity pressure was, however, a strong function of location. The tip cavity pressure distribution coupled with the pressure side distribution near the tip was speculated to drive the leakage flow across the blade tip from mid-chord aft based on surface flow visualization studies using an oil/dye mixture. Heat flux on the tip cavity floor was successfully measured using a thin-film Heat Flux Microsensor. Results of these measurements are consistent with previous studies in the subsonic regime. The convection coefficients on the tip cavity floor were found to be three times those found on the suction side airfoil surface near the trailing edge. Convection coefficients were found not to vary with either tip gap height or Mach number. The fluctuating component of heat flux was found to be at least 25% of the total heat flux.","abstract_has_math":false,"creators":["Yang, Timothy T."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Diller, Thomas E."],"committee_members":["O'Brien, Walter F. Jr.","Schetz, Joseph A."],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-07-22T22:20:05Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07112009-040445"],"render_values":[{"text":"etd-07112009-040445","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/43686","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Diller, Thomas E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["O'Brien, Walter F. Jr.","Schetz, Joseph A."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Yang, Timothy T."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:40:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:40:17Z","2009-07-11"]},{"key":"dc:date.issued","label":"Date","values":["1994"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07112009-040445"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/43686"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Gas turbine blade tip heat transfer and tip gap flow phenomena has been explored experimentally in a stationary cascade for blade exit Mach numbers = 1.2 to 1.4. Experimental results were found to agree well with qualitative predictions performed at GE Aircraft Engines. The pressure distribution in the blade tip cavity of a grooved tip blade was found to vary little with either Mach number or tip gap height. The tip cavity pressure was, however, a strong function of location. The tip cavity pressure distribution coupled with the pressure side distribution near the tip was speculated to drive the leakage flow across the blade tip from mid-chord aft based on surface flow visualization studies using an oil/dye mixture. Heat flux on the tip cavity floor was successfully measured using a thin-film Heat Flux Microsensor. Results of these measurements are consistent with previous studies in the subsonic regime. The convection coefficients on the tip cavity floor were found to be three times those found on the suction side airfoil surface near the trailing edge. Convection coefficients were found not to vary with either tip gap height or Mach number. The fluctuating component of heat flux was found to be at least 25% of the total heat flux."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["An experimental investigation of turbine blade tip heat transfer and tip gap flows in the supersonic regime"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Diller, Thomas E."],"dc:contributor.committeemember":["O'Brien, Walter F. Jr.","Schetz, Joseph A."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Yang, Timothy T."],"dc:date.accessioned":["2014-03-14T21:40:17Z"],"dc:date.available":["2014-03-14T21:40:17Z","2009-07-11"],"dc:date.issued":["1994"],"dc:description.abstract":["Gas turbine blade tip heat transfer and tip gap flow phenomena has been explored experimentally in a stationary cascade for blade exit Mach numbers = 1.2 to 1.4. Experimental results were found to agree well with qualitative predictions performed at GE Aircraft Engines. The pressure distribution in the blade tip cavity of a grooved tip blade was found to vary little with either Mach number or tip gap height. The tip cavity pressure was, however, a strong function of location. The tip cavity pressure distribution coupled with the pressure side distribution near the tip was speculated to drive the leakage flow across the blade tip from mid-chord aft based on surface flow visualization studies using an oil/dye mixture. Heat flux on the tip cavity floor was successfully measured using a thin-film Heat Flux Microsensor. Results of these measurements are consistent with previous studies in the subsonic regime. The convection coefficients on the tip cavity floor were found to be three times those found on the suction side airfoil surface near the trailing edge. Convection coefficients were found not to vary with either tip gap height or Mach number. The fluctuating component of heat flux was found to be at least 25% of the total heat flux."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-07112009-040445"],"dc:identifier.uri":["http://hdl.handle.net/10919/43686"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["An experimental investigation of turbine blade tip heat transfer and tip gap flows in the supersonic regime"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:05Z"}