Back to results

Virginia Tech

Effects of soil texture, soil depth, and treatment on septic tank effluent renovation

Abstract

dc:description.abstract

This study compared the effects of soil texture, soil depth, and additional treatment, by constructed wetland (CW) and recirculating sand filter (RSF) systems, on wastewater renovation in a texture group 2 (loam) and a texture group 3 (clay loam) soil. The soils with depths of 15, 30, and 45 cm were placed in the columns with a Gidding's hydraulic soil probe in order to retain the soils structure <i>in situ</i>. The texture group 2 columns were dosed with septic tank eflluent (STE), constructed wetland effluent (eWE), and recirculating sand filter effluent (RSFE) at 685 cm³ per day and the texture group 3 columns were dosed at 670 cm³ per day with the same effluents. These dosing events were split into 2 separate (12 h) events. The leachate from both groups of soil columns were analyzed for fecal coliforms (FC), biochemical oxygen demand (BODs), ammonium (NH₄-N), nitrate (NO₃-N), phosphate (PO₄-P), pH, total dissolved solids (TDS), electrical conductivity (EC), and chloride. In the texture group 2 soil the reduction in fecal coliform numbers was 88% and 99%, respectively, for the CW and the RSF and, in the texture group 3 soil was 91% and 99%, respectively, for the CW and the RSF. There was a reduction in BODs concentrations of 32% and 69% ,respectively, for the CW and the RSF. There was a 42% and 84% decrease in NH₄ concentrations, respectively, for the CW and the RSF. These reductions show that treatment of STE by CW or RSF can be substituted for soil depth in texture group 2 and 3 soils and will improve drainfield performance. Texture group 2 soils are less effective at STE renovation than texture group 3 soils at all soil depths. This was evidenced by higher FC counts and concentrations of BOD, N, and P in the leachates from these columns.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Crop and Soil Environmental Sciences
Department dc:contributor.department
Crop and Soil Environmental Sciences
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1995

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Keeling, William G.
Chair dc:contributor.committeechair
  • Reneau, Raymond B. Jr.
Committee members dc:contributor.committeemember
  • Hagedorn, Charles III
  • Martens, David C.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-06082009-171000
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/42906

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Keeling, William G.. Effects of soil texture, soil depth, and treatment on septic tank effluent renovation. masters thesis, Virginia Tech, 1995. http://hdl.handle.net/10919/42906