{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/42903"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/42903","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Adaptive feedback technique for unmodeled disturbance rejection","abstract":"This work presents experimental results of a hybrid control technique that blends traditional fixed feedback control with adaptive feedback techniques. The objective is to provide damping for transient disturbances via the fixed controller and rejection of steady disturbances via the adaptive controller. This technique differs from other control techniques in that it does not require a measurement of an external signal coherent with the disturbance, nor does it require knowledge of how the disturbance enters the system. As with all feedback techniques, stability is an issue. The adaptive controller is implemented to minimize stability problems and in the case of perfect system identification, it is guaranteed stability. The experimental results are from a cantilever beam with piezoceramic actuators and sensors. The fixed feedback controller results are compared to the adaptive feedback control results. The comparison will include results from disturbances resulting from a single harmonic, narrowband signal, and broadband signal.","abstract_html":"This work presents experimental results of a hybrid control technique that blends traditional fixed feedback control with adaptive feedback techniques. The objective is to provide damping for transient disturbances via the fixed controller and rejection of steady disturbances via the adaptive controller. This technique differs from other control techniques in that it does not require a measurement of an external signal coherent with the disturbance, nor does it require knowledge of how the disturbance enters the system. As with all feedback techniques, stability is an issue. The adaptive controller is implemented to minimize stability problems and in the case of perfect system identification, it is guaranteed stability. The experimental results are from a cantilever beam with piezoceramic actuators and sensors. The fixed feedback controller results are compared to the adaptive feedback control results. The comparison will include results from disturbances resulting from a single harmonic, narrowband signal, and broadband signal.","abstract_has_math":false,"creators":["Miller, Daniel H."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995","date_published":"1995","updated_at":"2026-07-22T22:20:31Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06082009-170945"],"render_values":[{"text":"etd-06082009-170945","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/42903","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Miller, Daniel H."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:37:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:37:08Z","2009-06-08"]},{"key":"dc:date.issued","label":"Date","values":["1995"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06082009-170945"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/42903"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work presents experimental results of a hybrid control technique that blends traditional fixed feedback control with adaptive feedback techniques. The objective is to provide damping for transient disturbances via the fixed controller and rejection of steady disturbances via the adaptive controller. This technique differs from other control techniques in that it does not require a measurement of an external signal coherent with the disturbance, nor does it require knowledge of how the disturbance enters the system. As with all feedback techniques, stability is an issue. The adaptive controller is implemented to minimize stability problems and in the case of perfect system identification, it is guaranteed stability. The experimental results are from a cantilever beam with piezoceramic actuators and sensors. The fixed feedback controller results are compared to the adaptive feedback control results. The comparison will include results from disturbances resulting from a single harmonic, narrowband signal, and broadband signal."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Adaptive feedback technique for unmodeled disturbance rejection"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Miller, Daniel H."],"dc:date.accessioned":["2014-03-14T21:37:08Z"],"dc:date.available":["2014-03-14T21:37:08Z","2009-06-08"],"dc:date.issued":["1995"],"dc:description.abstract":["This work presents experimental results of a hybrid control technique that blends traditional fixed feedback control with adaptive feedback techniques. The objective is to provide damping for transient disturbances via the fixed controller and rejection of steady disturbances via the adaptive controller. This technique differs from other control techniques in that it does not require a measurement of an external signal coherent with the disturbance, nor does it require knowledge of how the disturbance enters the system. As with all feedback techniques, stability is an issue. The adaptive controller is implemented to minimize stability problems and in the case of perfect system identification, it is guaranteed stability. The experimental results are from a cantilever beam with piezoceramic actuators and sensors. The fixed feedback controller results are compared to the adaptive feedback control results. The comparison will include results from disturbances resulting from a single harmonic, narrowband signal, and broadband signal."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-06082009-170945"],"dc:identifier.uri":["http://hdl.handle.net/10919/42903"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Adaptive feedback technique for unmodeled disturbance rejection"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:31Z"}