{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/42326"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/42326","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"A study of the cleaning and sanitizing of milk pipe lines","abstract":"The primary purpose of this investigation was to attempt to determine whether or not the stainless steel pipe line installation of the Virginia Polytechnic Institute creamery, composed of ordinary stainless steel, could be satisfactorily cleaned by circulation cleaning procedures as opposed to daily disassembly of the entire pipe line. To facilitate such a determination, two experimental periods of approximately thirty days each in duration were set up. In the first period the experimental pipe line was subjected to complete daily disassembly cleaning procedures. That is, each section of the line was disassembled, cleaned individually, and reassembled. In the second period the experimental line was subjected to in-place cleaning procedures. That is, the line was left completely intact and cleaning was accomplished by means of forced circulation of cleaning solutions in a manner comparable to the way the milk is forced through the line. The cleaning methods used in the second period necessitated the use or an acid cleaning solution twice weekly. Sanitizing in the first period was accomplished by the use of a chlorine rinse before use and in the second period both chlorine and hot water at 180 °F were used. The experimental installations consisted of fifty-six feet of raw milk line and twelve and one-half feet of pasteurized milk line.","abstract_html":"The primary purpose of this investigation was to attempt to determine whether or not the stainless steel pipe line installation of the Virginia Polytechnic Institute creamery, composed of ordinary stainless steel, could be satisfactorily cleaned by circulation cleaning procedures as opposed to daily disassembly of the entire pipe line. To facilitate such a determination, two experimental periods of approximately thirty days each in duration were set up. In the first period the experimental pipe line was subjected to complete daily disassembly cleaning procedures. That is, each section of the line was disassembled, cleaned individually, and reassembled. In the second period the experimental line was subjected to in-place cleaning procedures. That is, the line was left completely intact and cleaning was accomplished by means of forced circulation of cleaning solutions in a manner comparable to the way the milk is forced through the line. The cleaning methods used in the second period necessitated the use or an acid cleaning solution twice weekly. Sanitizing in the first period was accomplished by the use of a chlorine rinse before use and in the second period both chlorine and hot water at 180 °F were used. The experimental installations consisted of fifty-six feet of raw milk line and twelve and one-half feet of pasteurized milk line.","abstract_has_math":false,"creators":["Arnold, Carl Jefferson"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Dairy Husbandry","degree_department":"Dairy Husbandry","school":null,"contributors":[],"advisors":[],"committee_chairs":["Pardue, Louis A."],"committee_members":["Young, H. N.","Flora, Cornelia B."],"year":1952,"date_issued":"1952-08-16","date_published":"1952-08-16","updated_at":"2026-07-22T22:18:46Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04272010-020221"],"render_values":[{"text":"etd-04272010-020221","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/42326","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Pardue, Louis A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Young, H. N.","Flora, Cornelia B."]},{"key":"dc:contributor.department","label":"Department","values":["Dairy Husbandry"]},{"key":"dc:creator","label":"Author","values":["Arnold, Carl Jefferson"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:34:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:34:58Z","2010-04-27"]},{"key":"dc:date.issued","label":"Date","values":["1952-08-16"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dairy Husbandry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04272010-020221"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/42326"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The primary purpose of this investigation was to attempt to determine whether or not the stainless steel pipe line installation of the Virginia Polytechnic Institute creamery, composed of ordinary stainless steel, could be satisfactorily cleaned by circulation cleaning procedures as opposed to daily disassembly of the entire pipe line. To facilitate such a determination, two experimental periods of approximately thirty days each in duration were set up. In the first period the experimental pipe line was subjected to complete daily disassembly cleaning procedures. That is, each section of the line was disassembled, cleaned individually, and reassembled. In the second period the experimental line was subjected to in-place cleaning procedures. That is, the line was left completely intact and cleaning was accomplished by means of forced circulation of cleaning solutions in a manner comparable to the way the milk is forced through the line. The cleaning methods used in the second period necessitated the use or an acid cleaning solution twice weekly. Sanitizing in the first period was accomplished by the use of a chlorine rinse before use and in the second period both chlorine and hot water at 180 °F were used. The experimental installations consisted of fifty-six feet of raw milk line and twelve and one-half feet of pasteurized milk line."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A study of the cleaning and sanitizing of milk pipe lines"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Pardue, Louis A."],"dc:contributor.committeemember":["Young, H. N.","Flora, Cornelia B."],"dc:contributor.department":["Dairy Husbandry"],"dc:creator":["Arnold, Carl Jefferson"],"dc:date.accessioned":["2014-03-14T21:34:58Z"],"dc:date.available":["2014-03-14T21:34:58Z","2010-04-27"],"dc:date.issued":["1952-08-16"],"dc:description.abstract":["The primary purpose of this investigation was to attempt to determine whether or not the stainless steel pipe line installation of the Virginia Polytechnic Institute creamery, composed of ordinary stainless steel, could be satisfactorily cleaned by circulation cleaning procedures as opposed to daily disassembly of the entire pipe line. To facilitate such a determination, two experimental periods of approximately thirty days each in duration were set up. In the first period the experimental pipe line was subjected to complete daily disassembly cleaning procedures. That is, each section of the line was disassembled, cleaned individually, and reassembled. In the second period the experimental line was subjected to in-place cleaning procedures. That is, the line was left completely intact and cleaning was accomplished by means of forced circulation of cleaning solutions in a manner comparable to the way the milk is forced through the line. The cleaning methods used in the second period necessitated the use or an acid cleaning solution twice weekly. Sanitizing in the first period was accomplished by the use of a chlorine rinse before use and in the second period both chlorine and hot water at 180 °F were used. The experimental installations consisted of fifty-six feet of raw milk line and twelve and one-half feet of pasteurized milk line."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-04272010-020221"],"dc:identifier.uri":["http://hdl.handle.net/10919/42326"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["A study of the cleaning and sanitizing of milk pipe lines"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Dairy Husbandry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute"]},"updated_at":"2026-07-22T22:18:46Z"}