{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/42152"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/42152","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Integrity and effectiveness of standard preformed membranes placed on concrete bridge decks","abstract":"Waterproofing membranes have been used on bridge decks for almost three decades in order to prevent chloride ingress into concrete. However, the performance of these membranes have yet to be adequately evaluated. Therefore, this research was carried out primarily to evaluate the integrity and effectiveness of standard preformed membranes placed on concrete bridge decks. The actual conditions of a bridge deck were simulated in the laboratory using scaled-down reinforced concrete specimens. Forty-eight outdoor and twelve indoor specimens were cast. Three types of standard preformed membranes (Bithuthene 5000, Royston lOA, and Protecto Wrap M400-A), punctured with holes of various sizes and frequencies per unit area, were placed on the specimens. All of the specimens were overlaid with 2.5 inches of hot-mix asphalt, except four outdoor (control) specimens and three indoor specimens.","abstract_html":"Waterproofing membranes have been used on bridge decks for almost three decades in order to prevent chloride ingress into concrete. However, the performance of these membranes have yet to be adequately evaluated. Therefore, this research was carried out primarily to evaluate the integrity and effectiveness of standard preformed membranes placed on concrete bridge decks. The actual conditions of a bridge deck were simulated in the laboratory using scaled-down reinforced concrete specimens. Forty-eight outdoor and twelve indoor specimens were cast. Three types of standard preformed membranes (Bithuthene 5000, Royston lOA, and Protecto Wrap M400-A), punctured with holes of various sizes and frequencies per unit area, were placed on the specimens. All of the specimens were overlaid with 2.5 inches of hot-mix asphalt, except four outdoor (control) specimens and three indoor specimens.","abstract_has_math":false,"creators":["Galagedera, Nandadeva Lalith"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Weyers, Richard E."],"committee_members":["Al-Qadi, Imadeddin L.","Drew, Donald R.","Walker, Richard D."],"year":1991,"date_issued":"1991-09-09","date_published":"1991-09-09","updated_at":"2026-07-24T05:55:54Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04182009-041358"],"render_values":[{"text":"etd-04182009-041358","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/42152","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Weyers, Richard E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Al-Qadi, Imadeddin L.","Drew, Donald R.","Walker, Richard D."]},{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Galagedera, Nandadeva Lalith"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:34:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:34:13Z","2009-04-18"]},{"key":"dc:date.issued","label":"Date","values":["1991-09-09"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04182009-041358"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/42152"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Waterproofing membranes have been used on bridge decks for almost three decades in order to prevent chloride ingress into concrete. However, the performance of these membranes have yet to be adequately evaluated. Therefore, this research was carried out primarily to evaluate the integrity and effectiveness of standard preformed membranes placed on concrete bridge decks. The actual conditions of a bridge deck were simulated in the laboratory using scaled-down reinforced concrete specimens. Forty-eight outdoor and twelve indoor specimens were cast. Three types of standard preformed membranes (Bithuthene 5000, Royston lOA, and Protecto Wrap M400-A), punctured with holes of various sizes and frequencies per unit area, were placed on the specimens. All of the specimens were overlaid with 2.5 inches of hot-mix asphalt, except four outdoor (control) specimens and three indoor specimens."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Integrity and effectiveness of standard preformed membranes placed on concrete bridge decks"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Weyers, Richard E."],"dc:contributor.committeemember":["Al-Qadi, Imadeddin L.","Drew, Donald R.","Walker, Richard D."],"dc:contributor.department":["Civil Engineering"],"dc:creator":["Galagedera, Nandadeva Lalith"],"dc:date.accessioned":["2014-03-14T21:34:13Z"],"dc:date.available":["2014-03-14T21:34:13Z","2009-04-18"],"dc:date.issued":["1991-09-09"],"dc:description.abstract":["Waterproofing membranes have been used on bridge decks for almost three decades in order to prevent chloride ingress into concrete. However, the performance of these membranes have yet to be adequately evaluated. Therefore, this research was carried out primarily to evaluate the integrity and effectiveness of standard preformed membranes placed on concrete bridge decks. The actual conditions of a bridge deck were simulated in the laboratory using scaled-down reinforced concrete specimens. Forty-eight outdoor and twelve indoor specimens were cast. Three types of standard preformed membranes (Bithuthene 5000, Royston lOA, and Protecto Wrap M400-A), punctured with holes of various sizes and frequencies per unit area, were placed on the specimens. All of the specimens were overlaid with 2.5 inches of hot-mix asphalt, except four outdoor (control) specimens and three indoor specimens."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-04182009-041358"],"dc:identifier.uri":["http://hdl.handle.net/10919/42152"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Integrity and effectiveness of standard preformed membranes placed on concrete bridge decks"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-24T05:55:54Z"}