Comparison of laboratory protocols for yielding improved estimates of hearing protection in field performance for use in standards development

Abstract

dc:description.abstract

Federal law requires hearing protection device (HPD) manufacturers to provide attenuation ratings for use in estimating workers’ protection levels. These ratings, which are laboratory obtained, typically overestimate the actual protection levels achieved in the workplace. This research investigated laboratory protocols for yielding improved estimates of HPD in-field performance. Two experiments were conducted. The first was a pilot study developed by an American National Standards Institute (ANSI) working group. In this experiment, two types of earplugs were tested, a user-molded, malleable foam plug and a pre-molded, multi-sized rubber plug. Attenuation data (obtained using a psychoacoustical real-ear-attenuation-at-threshold measurement procedure) were collected across 10 subjects who entered the study as novice HPD users but were considered experienced HPD users in the latter half of the study. Four testing protocols involving two levels of HPDs, two levels of instruction-insertion techniques, and two levels of user experience were investigated. The same 10 subjects participated in all treatment conditions of the experiment. The second experiment involved similar protocols as the first; however, only one plug type was tested (the pre-molded, multi-sized rubber plug). Four testing protocols involving two levels of instruction-insertion techniques, two levels of user experience, and two levels of auditory feedback [fitting noise] were investigated. Forty subjects participated; each subject was tested in two treatment conditions. The attenuation results of each experiment were analyzed by statistical techniques. Statistical comparisons of results were made between the two experiments as well as between the experiments and selected field data. The major finding of the research was that fitting noise did not help subjects achieve higher attenuation [better protection] when consciously used for that purpose. Other findings indicated that novice subjects using only HPD manufacturer's instructions achieved attenuation that more closely represented the field attenuation than subjects tested under other conditions. However, the results were plug specific, in that no laboratory protocols yielded attenuation similar to the field data for the foam plug.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Industrial and Systems Engineering
Department dc:contributor.department
Industrial and Systems Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1991

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Richards, Michael Llewellyn

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-03172010-020615
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/41713

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Richards, Michael Llewellyn. Comparison of laboratory protocols for yielding improved estimates of hearing protection in field performance for use in standards development. masters thesis, Virginia Tech, 1991. http://hdl.handle.net/10919/41713