Back to results

Virginia Tech

Comparison of ion chromatography and flow injection analysis methods for monitoring chlorite and chlorate ions in drinking water

Abstract

dc:description.abstract

Up-coming regulations on chlorine dioxide in drinking water treatment require low level measurement of chlorite ion (CI0₂-) and chlorate ion (CI0₃-). This research investigated analysis of CI0₂- and CI0₃-; in drinking water by flow injection analysis with iodometric detection (FIA) and ion chromatography with conductivity detection (IC). Both the FIA and IC methods were accurate for the determination of CIO₂-; and CIO₃-; in reagent water. The IC method was accurate in drinking water, however, FIA responded to chloramines and other oxidants present in drinking water causing inaccurate analysis of CIO₂-; and CIO₃-; by FIA. The two IC eluants investigated, a carbonate/bicarbonate mixture and a borate/boric acid mixture, performed well. By taking advantage of the slightly different separation abilities of each eluant, the IC method can be modified to maximize resolution of CIO₂-; and CIO₃-; in different drinking water matrices. Chlorite was unstable in chlorinated drinking water but was stable for up to three days when sodium oxalate was added and stable up to eighteen days when ethylene diamine was added as a preservative. Chlorate was stable in drinking water for up to eighteen days with or without a preservative. The propagation of errors method for determining detection limits yielded limits of detection for CIO₂- (mg/L) of 0.05 for FIA, 0.03 for the IC carbonate eluant and 0.01 for the IC borate eluant. For CIO₃- the limits of detection (mg/L) were 0.24 for FIA; 0.11 for the IC carbonate eluant and 0.02 for the borate eluant.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Environmental Sciences and Engineering
Department dc:contributor.department
Environmental Sciences and Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1991

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ledder, Tracey

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-03172010-020312
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/41675

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Ledder, Tracey. Comparison of ion chromatography and flow injection analysis methods for monitoring chlorite and chlorate ions in drinking water. masters thesis, Virginia Tech, 1991. http://hdl.handle.net/10919/41675