{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/41594"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/41594","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Quadrature-point stabilization of Mach-Zehnder interferometers","abstract":"Optical fiber magnetometers are extremely sensitive devices which are capable of competing with magnetometers implemented using other technologies. Demodulation of the signals detected using these magnetometers can be performed using either homodyne or heterodyne techniques. Higher sensitivities have been achieved using homodyne rather than heterodyne techniques, but with homodyne demodulation there exists the inherent problem of quadrature-point stabilization. Presented here is a review of existing quadrature-point stabilization methods and experimental results concerning the application of one of them which uses a piezoelectric transducer in the reference arm of an all-fiber Mach-Zehnder interferometer.","abstract_html":"Optical fiber magnetometers are extremely sensitive devices which are capable of competing with magnetometers implemented using other technologies. Demodulation of the signals detected using these magnetometers can be performed using either homodyne or heterodyne techniques. Higher sensitivities have been achieved using homodyne rather than heterodyne techniques, but with homodyne demodulation there exists the inherent problem of quadrature-point stabilization. Presented here is a review of existing quadrature-point stabilization methods and experimental results concerning the application of one of them which uses a piezoelectric transducer in the reference arm of an all-fiber Mach-Zehnder interferometer.","abstract_has_math":false,"creators":["Ramchander, Rajesh"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990","date_published":"1990","updated_at":"2026-07-22T22:20:29Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03142009-040449"],"render_values":[{"text":"etd-03142009-040449","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/41594","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Ramchander, Rajesh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:31:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:31:38Z","2009-03-14"]},{"key":"dc:date.issued","label":"Date","values":["1990"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03142009-040449"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/41594"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Optical fiber magnetometers are extremely sensitive devices which are capable of competing with magnetometers implemented using other technologies. Demodulation of the signals detected using these magnetometers can be performed using either homodyne or heterodyne techniques. Higher sensitivities have been achieved using homodyne rather than heterodyne techniques, but with homodyne demodulation there exists the inherent problem of quadrature-point stabilization. Presented here is a review of existing quadrature-point stabilization methods and experimental results concerning the application of one of them which uses a piezoelectric transducer in the reference arm of an all-fiber Mach-Zehnder interferometer."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Quadrature-point stabilization of Mach-Zehnder interferometers"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Ramchander, Rajesh"],"dc:date.accessioned":["2014-03-14T21:31:38Z"],"dc:date.available":["2014-03-14T21:31:38Z","2009-03-14"],"dc:date.issued":["1990"],"dc:description.abstract":["Optical fiber magnetometers are extremely sensitive devices which are capable of competing with magnetometers implemented using other technologies. Demodulation of the signals detected using these magnetometers can be performed using either homodyne or heterodyne techniques. Higher sensitivities have been achieved using homodyne rather than heterodyne techniques, but with homodyne demodulation there exists the inherent problem of quadrature-point stabilization. Presented here is a review of existing quadrature-point stabilization methods and experimental results concerning the application of one of them which uses a piezoelectric transducer in the reference arm of an all-fiber Mach-Zehnder interferometer."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-03142009-040449"],"dc:identifier.uri":["http://hdl.handle.net/10919/41594"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Quadrature-point stabilization of Mach-Zehnder interferometers"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:29Z"}