{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/41591"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/41591","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Transplant organ preservation cooler","abstract":"A method for preserving transplant organs for extended periods of time has been developed in the transplant organ preservation cooler. The preservation cooler enhances organ viability by maintaining a temperature controlled organ bath and pumping perfusate through the transplant organ. The emphasis on the transplant organ preservation cooler is to provide a simple and portable system which will be powered by boiled off oxygen from a liquid oxygen source. The design of the preservation cooler pump and temperature control system are presented. Results of tests proving the successful operation of the preservation cooler prototype are also presented.","abstract_html":"A method for preserving transplant organs for extended periods of time has been developed in the transplant organ preservation cooler. The preservation cooler enhances organ viability by maintaining a temperature controlled organ bath and pumping perfusate through the transplant organ. The emphasis on the transplant organ preservation cooler is to provide a simple and portable system which will be powered by boiled off oxygen from a liquid oxygen source. The design of the preservation cooler pump and temperature control system are presented. Results of tests proving the successful operation of the preservation cooler prototype are also presented.","abstract_has_math":false,"creators":["Poliachik, Sandra Louise"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991","date_published":"1991","updated_at":"2026-07-22T22:20:08Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03142009-040431"],"render_values":[{"text":"etd-03142009-040431","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/41591","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Poliachik, Sandra Louise"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:31:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:31:37Z","2009-03-14"]},{"key":"dc:date.issued","label":"Date","values":["1991"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03142009-040431"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/41591"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A method for preserving transplant organs for extended periods of time has been developed in the transplant organ preservation cooler. The preservation cooler enhances organ viability by maintaining a temperature controlled organ bath and pumping perfusate through the transplant organ. The emphasis on the transplant organ preservation cooler is to provide a simple and portable system which will be powered by boiled off oxygen from a liquid oxygen source. The design of the preservation cooler pump and temperature control system are presented. Results of tests proving the successful operation of the preservation cooler prototype are also presented."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Transplant organ preservation cooler"]}]}],"canonical_facts":{"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Poliachik, Sandra Louise"],"dc:date.accessioned":["2014-03-14T21:31:37Z"],"dc:date.available":["2014-03-14T21:31:37Z","2009-03-14"],"dc:date.issued":["1991"],"dc:description.abstract":["A method for preserving transplant organs for extended periods of time has been developed in the transplant organ preservation cooler. The preservation cooler enhances organ viability by maintaining a temperature controlled organ bath and pumping perfusate through the transplant organ. The emphasis on the transplant organ preservation cooler is to provide a simple and portable system which will be powered by boiled off oxygen from a liquid oxygen source. The design of the preservation cooler pump and temperature control system are presented. Results of tests proving the successful operation of the preservation cooler prototype are also presented."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-03142009-040431"],"dc:identifier.uri":["http://hdl.handle.net/10919/41591"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Transplant organ preservation cooler"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:20:08Z"}