{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/41202"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/41202","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Bacterial coagulation by a chlorinated solvent","abstract":"This investigation has led to the following conclusions: 1. Good removals of most bacterial species were observed. 2. Increased length of settling time increased the percent removal of pure cultures. 3. The solvent coagulation process worked best at a pH very near the pH produced by the bacteria during growth. 4. There was no advantage in changing from room temperature. S. proper surface active agents aided in the coagulation of bacteria in the solvent ooagulation process. 6. Almost all of the bacteria in suspension after the coagulation process were not viable. 7. Good removals were observed using the solvent coagulation process on mixed cultures. 8. The chlorinated solvent coagulation process shows promise for commercial operations.","abstract_html":"This investigation has led to the following conclusions: 1. Good removals of most bacterial species were observed. 2. Increased length of settling time increased the percent removal of pure cultures. 3. The solvent coagulation process worked best at a pH very near the pH produced by the bacteria during growth. 4. There was no advantage in changing from room temperature. S. proper surface active agents aided in the coagulation of bacteria in the solvent ooagulation process. 6. Almost all of the bacteria in suspension after the coagulation process were not viable. 7. Good removals were observed using the solvent coagulation process on mixed cultures. 8. The chlorinated solvent coagulation process shows promise for commercial operations.","abstract_has_math":false,"creators":["Blackwell, Richard Lee"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Sanitary Engineering","degree_department":"Sanitary Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Bungay, Henry R. III"],"committee_members":["Parsons, William A."],"year":1965,"date_issued":"1965-08-02","date_published":"1965-08-02","updated_at":"2026-07-22T22:20:02Z","subjects":[],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02162010-020504"],"render_values":[{"text":"etd-02162010-020504","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/41202","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Bungay, Henry R. III"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Parsons, William A."]},{"key":"dc:contributor.department","label":"Department","values":["Sanitary Engineering"]},{"key":"dc:creator","label":"Author","values":["Blackwell, Richard Lee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:29:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:29:57Z","2010-02-16"]},{"key":"dc:date.issued","label":"Date","values":["1965-08-02"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Sanitary Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02162010-020504"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/41202"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This investigation has led to the following conclusions: 1. Good removals of most bacterial species were observed. 2. Increased length of settling time increased the percent removal of pure cultures. 3. The solvent coagulation process worked best at a pH very near the pH produced by the bacteria during growth. 4. There was no advantage in changing from room temperature. S. proper surface active agents aided in the coagulation of bacteria in the solvent ooagulation process. 6. Almost all of the bacteria in suspension after the coagulation process were not viable. 7. Good removals were observed using the solvent coagulation process on mixed cultures. 8. The chlorinated solvent coagulation process shows promise for commercial operations."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Bacterial coagulation by a chlorinated solvent"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Bungay, Henry R. III"],"dc:contributor.committeemember":["Parsons, William A."],"dc:contributor.department":["Sanitary Engineering"],"dc:creator":["Blackwell, Richard Lee"],"dc:date.accessioned":["2014-03-14T21:29:57Z"],"dc:date.available":["2014-03-14T21:29:57Z","2010-02-16"],"dc:date.issued":["1965-08-02"],"dc:description.abstract":["This investigation has led to the following conclusions: 1. Good removals of most bacterial species were observed. 2. Increased length of settling time increased the percent removal of pure cultures. 3. The solvent coagulation process worked best at a pH very near the pH produced by the bacteria during growth. 4. There was no advantage in changing from room temperature. S. proper surface active agents aided in the coagulation of bacteria in the solvent ooagulation process. 6. Almost all of the bacteria in suspension after the coagulation process were not viable. 7. Good removals were observed using the solvent coagulation process on mixed cultures. 8. The chlorinated solvent coagulation process shows promise for commercial operations."],"dc:description.degree":["Master of Science"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-02162010-020504"],"dc:identifier.uri":["http://hdl.handle.net/10919/41202"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["Bacterial coagulation by a chlorinated solvent"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Sanitary Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute"]},"updated_at":"2026-07-22T22:20:02Z"}